| 制造商料号 | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() PF40561BX-Q020-S99 | SUNON 12V 16.68W 40x40x56mm 53.9m3/h DC Axial Fan for Industrial Cooling Equipment designers working with servers and data-center electronics can evaluate SUNON PF40561BX-Q020-S99, a DC axial fan rated at 12 VDC and sized 40 × 40 × 56 mm. 936.6 Pa maximum pressure is the standout documented duty-point value. Review its technical profile during spares assessment. Confirm control inputs against the complete ordering code. |
12 | 40x40x56 | 53.9 | 936.6 | 16.68 | 18000/21500 | 65.9 | |
![]() PF80251B1-0000-F99 | SUNON 12V 4.1W 80x80x25mm 101.9m3/h DC Axial Fan for Industrial Cooling The PF80251B1-0000-F99 is SUNON's 12 VDC, 80 × 80 × 25 mm DC axial fan option for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. Treat the model record as a primary input to spares assessment. Confirm control inputs against the complete ordering code. |
12 | 80x80x25mm | 101.9 | 102.1 | 4.1 | 4800 | 47.5 | |
![]() PF40281B1-Q000-S99 | SUNON 12V 6.12W 40x40x28mm 42.3m3/h DC Axial Fan for Industrial Cooling For thermal management in servers and data-center electronics, the PF40281B1-Q000-S99 provides a 12 VDC DC axial fan configuration measuring 40 × 40 × 28 mm. 17600 rpm is the model's most distinctive operating parameter. Base spares assessment on the stated product configuration. Confirm control inputs against the complete ordering code. |
12 | 40x40x28mm | 42.3 | 510.6 | 6.12 | 17600 | 56 | |
![]() PF92251V3-1000U-A99 | SUNON 12V 2.76W 92x92x25mm 109.2m3/h DC Axial Fan for Industrial Cooling SUNON PF92251V3-1000U-A99 combines a 92 × 92 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. Up to 109.2 m³/h is its most prominent listed performance figure. During spares assessment, compare the model's system interface. Confirm control inputs against the complete ordering code. |
12 | 92x92x25 | 109.2 | 62.3 | 2.76 | 3900 | 41.6 | |
![]() GF92382B1-10000-SDP | SUNON 24V 7200W 40x40x28mm 246.9m3/h DC Axial Fan for Industrial Cooling For airflow duties across servers and data-center electronics, the GF92382B1-10000-SDP provides a 24 VDC DC axial fan configuration measuring 40 × 40 × 28 mm. 7200 W input is the defining electrical load in the supplied data. Treat the rated dataset as a primary input to spares assessment. Confirm control inputs against the complete ordering code. |
24 | 40x40x28mm | 246.9 | 298.9 | 7200 | 7200 | 60.6 | |
![]() GF80382BX-10000-SDP | SUNON 24V 10000W 40x40x28mm 226m3/h DC Axial Fan for Industrial Cooling Within servers and data-center electronics, SUNON GF80382BX-10000-SDP serves as a 40 × 40 × 28 mm DC axial fan operating at 24 VDC. 10000 W input is the defining electrical load in the supplied data. Treat the electrical load as a primary input to spares assessment. Confirm control inputs against the complete ordering code. |
24 | 40x40x28mm | 226 | 438.4 | 10000 | 10000 | 64.3 | |
![]() GF80382BX-10000-QDP | SUNON 24V 10000W 40x40x28mm 226m3/h DC Axial Fan for Industrial Cooling Equipment designers working with servers and data-center electronics can evaluate SUNON GF80382BX-10000-QDP, a DC axial fan rated at 24 VDC and sized 40 × 40 × 28 mm. 10000 W input is the defining electrical load in the supplied data. Base spares assessment on the stated speed benchmark. Confirm control inputs against the complete ordering code. |
24 | 40x40x28mm | 226 | 438.4 | 10000 | 10000 | 64.3 | |
![]() GF80382B1-10000-SDP | SUNON 24V 8000W 40x40x28mm 182.3m3/h DC Axial Fan for Industrial Cooling SUNON GF80382B1-10000-SDP combines a 40 × 40 × 28 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. 8000 W input is the defining electrical load in the supplied data. For fan selection, start with the supplied technical profile. Use current model documentation to validate protection choices. |
24 | 40x40x28mm | 182.3 | 284 | 8000 | 8000 | 59.6 | |
![]() GF80382B1-10000-QDP | SUNON 24V 8000W 40x40x28mm 182.3m3/h DC Axial Fan for Industrial Cooling Designed for servers and data-center electronics, SUNON GF80382B1-10000-QDP is a 24 VDC DC axial fan in a 40 × 40 × 28 mm frame. 8000 W input is the defining electrical load in the supplied data. Use the documented model record when planning fan selection. Use current model documentation to validate protection choices. |
24 | 40x40x28mm | 182.3 | 284 | 8000 | 8000 | 59.6 | |
![]() GF60252BX-10000-SDP | SUNON 24V 12900W 40x40x28mm 93.1m3/h DC Axial Fan for Industrial Cooling The GF60252BX-10000-SDP is SUNON's 24 VDC, 40 × 40 × 28 mm DC axial fan option for servers and data-center electronics. 12900 W input is the defining electrical load in the supplied data. For fan selection, start with the supplied acoustic value. Use current model documentation to validate protection choices. |
24 | 40x40x28mm | 93.1 | 358.7 | 12900 | 12900 | 55.4 | |
![]() GF60252BX-10000-QDP | SUNON 24V 12900W 40x40x28mm 93.1m3/h DC Axial Fan for Industrial Cooling GF60252BX-10000-QDP serves servers and data-center electronics as a 40 × 40 × 28 mm DC axial fan rated at 24 VDC. 12900 W input is the defining electrical load in the supplied data. Use the documented electrical load when planning fan selection. Use current model documentation to validate protection choices. |
24 | 40x40x28mm | 93.1 | 358.7 | 12900 | 12900 | 55.4 | |
![]() GF60252B3-10000-SDP | SUNON 24V 6450W 40x40x28mm 46.6m3/h DC Axial Fan for Industrial Cooling Within servers and data-center electronics, SUNON GF60252B3-10000-SDP serves as a 40 × 40 × 28 mm DC axial fan operating at 24 VDC. 6450 W input is the defining electrical load in the supplied data. Base cooling-margin review on the stated application data. Check the full suffix before confirming connector details. |
24 | 40x40x28mm | 46.6 | 94.7 | 6450 | 6450 | 41.7 | |
![]() GF60252B3-10000-QDP | SUNON 24V 6450W 40x40x28mm 46.6m3/h DC Axial Fan for Industrial Cooling The 40 × 40 × 28 mm GF60252B3-10000-QDP brings 24 VDC DC axial fan cooling to servers and data-center electronics. 6450 W input is the defining electrical load in the supplied data. During cooling-margin review, compare the model's technical profile. Check the full suffix before confirming connector details. |
24 | 40x40x28mm | 46.6 | 94.7 | 6450 | 6450 | 41.7 | |
![]() GF60252B2-10000-SDP | SUNON 24V 9000W 40x40x28mm 65.1m3/h DC Axial Fan for Industrial Cooling SUNON GF60252B2-10000-SDP combines a 40 × 40 × 28 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. 9000 W input is the defining electrical load in the supplied data. Use the documented system interface when planning cooling-margin review. Check the full suffix before confirming connector details. |
24 | 40x40x28mm | 65.1 | 186.8 | 9000 | 9000 | 48.9 | |
![]() GF60252B2-10000-QDP | SUNON 24V 9000W 40x40x28mm 65.1m3/h DC Axial Fan for Industrial Cooling Engineered for servers and data-center electronics, SUNON GF60252B2-10000-QDP is a 24 VDC DC axial fan in a 40 × 40 × 28 mm frame. 9000 W input is the defining electrical load in the supplied data. Review its cooling specification during cooling-margin review. Check the full suffix before confirming connector details. |
24 | 40x40x28mm | 65.1 | 186.8 | 9000 | 9000 | 48.9 | |
![]() GF60252B1-10000-SDP | SUNON 24V 11500W 40x40x28mm 82.9m3/h DC Axial Fan for Industrial Cooling The GF60252B1-10000-SDP is SUNON's 24 VDC, 40 × 40 × 28 mm DC axial fan option for servers and data-center electronics. 11500 W input is the defining electrical load in the supplied data. During cooling-margin review, compare the model's selection parameters. Check the full suffix before confirming connector details. |
24 | 40x40x28mm | 82.9 | 306.4 | 11500 | 11500 | 52.7 | |
![]() GF60252B1-10000-QDP | SUNON 24V 11500W 40x40x28mm 82.9m3/h DC Axial Fan for Industrial Cooling For thermal management in servers and data-center electronics, the GF60252B1-10000-QDP provides a 24 VDC DC axial fan configuration measuring 40 × 40 × 28 mm. 11500 W input is the defining electrical load in the supplied data. The recorded rated dataset should guide cooling-margin review. Check the full suffix before confirming connector details. |
24 | 40x40x28mm | 82.9 | 306.4 | 11500 | 11500 | 52.7 | |
![]() GF40282BX-10000-SDP | SUNON 24V 17600W 40x40x28mm 41.8m3/h DC Axial Fan for Industrial Cooling The GF40282BX-10000-SDP is SUNON's 24 VDC, 40 × 40 × 28 mm DC axial fan option for servers and data-center electronics. 17600 W input is the defining electrical load in the supplied data. Treat the volume-flow figure as a primary input to cooling-margin review. Check the full suffix before confirming connector details. |
24 | 40x40x28mm | 41.8 | 515.6 | 17600 | 17600 | 58.1 | |
![]() GF40282BX-10000-QDP | SUNON 24V 17600W 40x40x28mm 41.8m3/h DC Axial Fan for Industrial Cooling For ventilation needs in servers and data-center electronics, the GF40282BX-10000-QDP provides a 24 VDC DC axial fan configuration measuring 40 × 40 × 28 mm. 17600 W input is the defining electrical load in the supplied data. Base cooling-margin review on the stated sound level. Check the full suffix before confirming connector details. |
24 | 40x40x28mm | 41.8 | 515.6 | 17600 | 17600 | 58.1 | |
![]() GF40282B3-10000-SDP | SUNON 24V 10500W 40x40x28mm 25m3/h DC Axial Fan for Industrial Cooling Within servers and data-center electronics, SUNON GF40282B3-10000-SDP serves as a 40 × 40 × 28 mm DC axial fan operating at 24 VDC. 10500 W input is the defining electrical load in the supplied data. For cooling-margin review, start with the supplied frame geometry. Check the full suffix before confirming connector details. |
24 | 40x40x28mm | 25 | 181.8 | 10500 | 10500 | 46.8 |
选择合适的工业冷却,应从工作点出发而不是从型号名称出发。先确定您实际需要的风量(CFM 或 m³/h)以及风机需要克服的静压,再寻找性能曲线能以一定裕量穿过该工作点的机型,而不是刚好压在曲线边缘的产品。
电气细节要尽早确认。DC 风机通常采用 12/24/48 V 供电,易于与控制板集成;AC 风机适合 115/230 V 定速安装场合。如果风量需要随负载变化,请选择支持 PWM 或模拟量控制的 EC 技术;在需要状态监控的场合,测速输出可以让控制器及时发现风机故障。
下一步是环境与认证。根据粉尘和潮湿暴露程度匹配 IP 防护等级,凡在高温、立式或全天候连续运行的场合,优先选择滚珠轴承,并对照目标市场确认 UL、CE、RoHS 等认证。尽早以 dBA 设定声学限值,可以避免第一台样机噪声过大时的后期返工。
最后,请从整体供货风险而非单纯价格来比较候选型号:确认所需数量的现货情况,核实后续批次的交期,并在确认前索取规格书和尺寸图。报价前,我们的团队会为您交叉核对曲线、尺寸和电气参数 该分类目前有 642 件产品可供对比。
工业冷却几乎出现在所有需要可靠排热或换气的行业。典型环境包括机房与数据中心、制冷冷凝器与冷库蒸发器、暖通空调组合式空调机组、通信机柜、医疗与实验室设备、焊接与数控机床机壳,以及新能源电力柜。在这些场景中,风机都是关键部件:一旦故障就意味着停产、货物受损或代价高昂的紧急停机。
一个反复出现的场景来自控制柜改造:原装风机已停产,安装孔位不能改动,停机时间以小时计。我们按机壳尺寸、风量和噪音将旧型号与在产系列逐一比对,提出最接近的直接替换方案,并随货附上规格书,让电工无需重新设计即可接线。
对冷库运营方来说,痛点很直接:蒸发器或冷凝器风机故障必须立即更换,而不是等六周的进口周期。将叶轮直径、转速和防护等级与现货等效型号逐一比对,我们能在几天内恢复制冷能力——备件替换供应也因此成为我们在该分类下的核心业务。
无论您是在制造新设备还是维护既有设备,流程都一样:把工作点和约束条件发给我们,我们回报经过验证的选型结果,并附规格书、性能曲线和明确的交期。
常规系列和主流电压版本通常备有现货,可在几个工作日内发货;特殊或定制版本按订单生产,一般需要额外的生产时间。您只需提供确切型号或所需参数,我们将在一次回复中确认库存、单价和最早发货日期,该分类目前在线展示 642 件产品。
可以。备件替换供应是我们的核心服务之一:我们会逐一核对您在用机组的安装尺寸、电压、转速和性能曲线,提出最接近的在产系列等效型号。如机壳或接口略有差异,我们会在下单前明确告知差异,确保替换安装不出现意外。
欢迎单件订购和样品申请——许多客户都会先在系统中验证一台样机,再决定批量采购。标准现货型号不设最低起订量,且多数复购订单可在批量货款中抵扣样品费。请告诉我们计划使用的数量,我们将同时给出两种方案的报价。
袋装
袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。