| 制造商料号 | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() A6D630-AD01-01 | ebm-papst 400V 710W AC Axial Fan for Refrigeration The A6D630-AD01-01 from ebm-papst combines 400 V operation with an AC axial fan configuration for refrigeration and cooling equipment. Its documented 12000 m³/h airflow, 224 Pa pressure, 860 RPM helps engineers compare the fan with the system resistance, installation space and cooling demand. |
400 | 630 | 12000 | 224 | 710 | 860 | - | |
![]() 9GT0912P4J001 | Sanyo Denki 12VDC 5.04W DC Axial Fan for refrigeration and electrical equipment cooling Within servers, UPS systems, and telecom equipment, Sanyo Denki 9GT0912P4J001 operates as a 92×92×25 mm DC axial fan at 12 VDC. The series cooling function is confirmed; suffix-specific options require datasheet verification. Its listed airflow of 132 m³/h is the standout performance value. Selection focus: compatibility risk checking motor input. |
12 | 92×92×25 | 132 | 105 | 5.04 | 5000 | 44 | |
![]() 9GT0412P3J001 | Sanyo Denki 12VDC 3.72W DC Axial Fan for refrigeration and electrical equipment cooling For thermal management in servers, UPS systems, and telecom equipment, the 9GT0412P3J001 provides a 12 VDC DC axial fan configuration measuring 40 × 40 × 28 mm. 11700 rpm is the model's most prominent operating value. The recorded operating point should guide duty-point matching. Treat bearing and life data as suffix-specific. |
12 | 40*40*28 | 31.28 | 206 | 3.72 | 11700 | 48 | |
![]() 9GT0624P4G001 | Sanyo Denki 24VDC 6.72W DC Axial Fan for refrigeration and electrical equipment cooling Equipment designers serving servers, UPS systems, and telecom equipment can evaluate Sanyo Denki 9GT0624P4G001, a DC axial fan rated at 24 VDC and sized 60×60×25 mm. 10000 rpm is the model's most prominent operating value. During equipment integration, compare the model's performance curve. Review connector, alarm, and sensor options separately. |
24 | 60×60×25 | 75.6 | 243 | 6.72 | 10000 | 52 | |
![]() 9GT0424P3J001 | Sanyo Denki 24VDC 3.6W DC Axial Fan for refrigeration and electrical equipment cooling Within servers, UPS systems, and telecom equipment, Sanyo Denki 9GT0424P3J001 operates as a 40 × 40 × 28 mm DC axial fan at 24 VDC. The series cooling function is confirmed; suffix-specific options require datasheet verification. 11700 rpm is the model's most prominent operating value. Selection focus: thermal margin assessment rated dataset. |
24 | 40*40*28 | 31.28 | 206 | 3.6 | 11700 | 48 | |
![]() 9GT1224P1S001 | Sanyo Denki 24VDC 26.4W DC Axial Fan for refrigeration and electrical equipment cooling The 24 VDC Sanyo Denki 9GT1224P1S001 is a DC axial fan sized 120 × 120 × 38 mm for servers, UPS systems, and telecom equipment. The series cooling function is confirmed; suffix-specific options require datasheet verification. Its listed airflow of 360.06 m³/h is the standout performance value. Focus: control interface planning cooling output. |
24 | 120*120*38 | 360.06 | 269 | 26.4 | 5600 | 58 | |
![]() 9GT0824P4S001 | Sanyo Denki 24VDC 5.28W DC Axial Fan for refrigeration and electrical equipment cooling For thermal management in servers, UPS systems, and telecom equipment, the 9GT0824P4S001 provides a 24 VDC DC axial fan configuration measuring 80 × 80 × 25 mm. 6700 rpm is the model's most prominent operating value. The recorded equipment fit should guide thermal validation. Obtain the applicable curve before final duty-point approval. |
24 | 80*80*25 | 111.69 | 143 | 5.28 | 6700 | 46 | |
![]() SF23080AT-2082HBL.GN | SUNON 240V 13.5W 80x80x25.50mm AC Axial Fan for Refrigeration Equipment SUNON SF23080AT-2082HBL.GN combines a 80 × 80 × 25.50 mm AC axial fan platform with a 240 VAC rating for commercial refrigeration and refrigerator cooling. Its 2900 rpm rating defines a lower-speed operating point. Base project documentation on the stated system interface. Reconcile the model code with the required electrical interface. |
240 | 80x80x25.50 | 37 | 47.3 | 13.5 | 2900 | 34.5 | |
![]() EFC0382B3-10000-A9H | SUNON 24V 1.8W 120x120x38mm DC Axial Fan for Refrigeration Equipment For telecom cabinets, base stations, and network equipment, EFC0382B3-10000-A9H combines 24 VDC operation with a 120 × 120 × 38 mm DC axial fan design. Its 2400 rpm rating defines a lower-speed operating point. The recorded speed benchmark should guide specification approval. Check the ordering suffix before assigning control functions. |
24 | 120x120x38mm | 158 | 47.3 | 1.8 | 2400 | 36 | |
![]() EFC0382B2-10000-A9H | SUNON 24V 3.24W 120x120x38mm DC Axial Fan for Refrigeration Equipment The EFC0382B2-10000-A9H is SUNON's 24 VDC, 120 × 120 × 38 mm DC axial fan option for telecom cabinets, base stations, and network equipment. Up to 197.1 m³/h is its most prominent listed performance figure. For specification approval, start with the supplied airflow profile. Check the ordering suffix before assigning control functions. |
24 | 120x120x38mm | 197.1 | 72.2 | 3.24 | 3100 | 43.2 | |
![]() EFC0382B1-10000-A9H | SUNON 24V 4.68W 120x120x38mm DC Axial Fan for Refrigeration Equipment SUNON EFC0382B1-10000-A9H is a 24 VDC DC axial fan for telecom cabinets, base stations, and network equipment. Up to 234.5 m³/h is its most prominent listed performance figure. Use the documented application data when planning heat-load assessment. Use the latest specification for frequency and tolerance limits. |
24 | 120x120x38mm | 234.5 | 99.6 | 4.68 | 3700 | 48 | |
![]() EFC0381B3-10000-A9H | SUNON 12V 1.5W 120x120x38mm DC Axial Fan for Refrigeration Equipment SUNON EFC0381B3-10000-A9H combines a 120 × 120 × 38 mm DC axial fan platform with a 12 VDC rating for telecom cabinets, base stations, and network equipment. Its 2400 rpm rating defines a lower-speed operating point. Review its technical profile during heat-load assessment. Use the latest specification for frequency and tolerance limits. |
12 | 120x120x38mm | 158 | 47.3 | 1.5 | 2400 | 36 | |
![]() EFC0381B2-10000-A9H | SUNON 12V 2.94W 120x120x38mm DC Axial Fan for Refrigeration Equipment Built around telecom cabinets, base stations, and network equipment, SUNON EFC0381B2-10000-A9H is a 12 VDC DC axial fan in a 120 × 120 × 38 mm frame. Up to 197.1 m³/h is its most prominent listed performance figure. Treat the model record as a primary input to heat-load assessment. Use the latest specification for frequency and tolerance limits. |
12 | 120x120x38mm | 197.1 | 72.2 | 2.94 | 3100 | 43.2 | |
![]() EFC0381B1-10000-A9H | SUNON 12V 4.26W 120x120x38mm DC Axial Fan for Refrigeration Equipment Within telecom cabinets, base stations, and network equipment, SUNON EFC0381B1-10000-A9H serves as a 120 × 120 × 38 mm DC axial fan operating at 12 VDC. Up to 234.5 m³/h is its most prominent listed performance figure. Base heat-load assessment on the stated product configuration. Use the latest specification for frequency and tolerance limits. |
12 | 120x120x38mm | 234.5 | 99.6 | 4.26 | 3700 | 48 | |
![]() EF92252S1-10000-A99 | SUNON 24V 1.44W 92x92x25mm DC Axial Fan for Refrigeration Equipment A 92 × 92 × 25 mm frame and 24 VDC rating define EF92252S1-10000-A99, a DC axial fan for telecom cabinets, base stations, and network equipment. Its 3000 rpm rating defines a lower-speed operating point. During heat-load assessment, compare the model's system interface. Use the latest specification for frequency and tolerance limits. |
24 | 92x92x25mm | 87.5 | 37.4 | 1.44 | 3000 | 34 | |
![]() EF92252BX-10000-A99 | SUNON 24V 2.16W 92x92x25mm DC Axial Fan for Refrigeration Equipment The EF92252BX-10000-A99 is SUNON's 24 VDC, 92 × 92 × 25 mm DC axial fan option for telecom cabinets, base stations, and network equipment. Up to 93.4 m³/h is its most prominent listed performance figure. The recorded cooling specification should guide heat-load assessment. Use the latest specification for frequency and tolerance limits. |
24 | 92x92x25mm | 93.4 | 52.3 | 2.16 | 3400 | 36.9 | |
![]() EF92252B2-10000-A99 | SUNON 24V 1.08W 92x92x25mm DC Axial Fan for Refrigeration Equipment Within telecom cabinets, base stations, and network equipment, EF92252B2-10000-A99 provides a 92 × 92 × 25 mm, 24 VDC DC axial fan configuration. Its 2700 rpm rating defines a lower-speed operating point. For heat-load assessment, start with the supplied duty-point values. Use the latest specification for frequency and tolerance limits. |
24 | 92x92x25mm | 76.5 | 37.4 | 1.08 | 2700 | 32 | |
![]() EF92252B1-10000-A99 | SUNON 24V 1.52W 92x92x25mm DC Axial Fan for Refrigeration Equipment The 24 VDC SUNON EF92252B1-10000-A99 is a DC axial fan sized 92 × 92 × 25 mm for telecom cabinets, base stations, and network equipment. Its 3000 rpm rating defines a lower-speed operating point. Use the documented installation footprint when planning heat-load assessment. Use the latest specification for frequency and tolerance limits. |
24 | 92x92x25mm | 87.5 | 42.3 | 1.52 | 3000 | 34 | |
![]() EF92251S3-10000-A99 | SUNON 12V 0.96W 92x92x25mm DC Axial Fan for Refrigeration Equipment Configured for telecom cabinets, base stations, and network equipment, SUNON EF92251S3-10000-A99 is a 12 VDC DC axial fan in a 92 × 92 × 25 mm frame. Its 2400 rpm rating defines a lower-speed operating point. Review its selection parameters during heat-load assessment. Use the latest specification for frequency and tolerance limits. |
12 | 92x92x25mm | 67.1 | 24.9 | 0.96 | 2400 | 28 | |
![]() EF92251S2-10000-A99 | SUNON 12V 1.32W 92x92x25mm DC Axial Fan for Refrigeration Equipment Within telecom cabinets, base stations, and network equipment, SUNON EF92251S2-10000-A99 serves as a 92 × 92 × 25 mm DC axial fan operating at 12 VDC. Its 2700 rpm rating defines a lower-speed operating point. Treat the rated dataset as a primary input to heat-load assessment. Use the latest specification for frequency and tolerance limits. |
12 | 92x92x25mm | 76.5 | 32.4 | 1.32 | 2700 | 32 |
在对比制冷设备的型号之前,先列明真实的运行需求:所需风量、系统静压、可用安装空间和现场供电条件。忽略这四项因素中任何一项的选型,通常最终都会以退货或现场改造收场。
电压和控制方式决定入围范围。标准选项包括 12/24/48 V DC 和 115/230 V AC;对于工作点会变化的场合,支持 PWM 或 0-10 V 输入的 EC 风机可实现精准调速,测速信号则能提供许多安全系统所需的反馈。
环境条件比任何目录筛选器都更快地淘汰不合适的型号。检查环境温度范围、防尘防潮所需的 IP 防护等级以及预期使用寿命——在立式安装或高温位置,滚珠轴承机型保持噪音和风量指标稳定的时间远长于含油轴承设计。如果设备要销往受监管市场,应在此阶段确认 UL、CE 和 RoHS 认证,并尽早设定以 dBA 为单位的噪音目标,避免声学问题在安装后才暴露。
收尾阶段要为订单排除风险:核实库存水平,确认生产交期,并索取候选型号的规格书和尺寸图,确保安装孔位和接口在采购前核对无误。把您的工作点提供给我们,我们将验证匹配性 该分类现有 370 件产品可随时对比。
从我们的项目记录看,凡是设备需要持续散热、空气需要持续流动的场合都会用到制冷设备:数据中心与机房、商用制冷、空调通风系统、通信与电池柜、工业机械设备,以及新能源领域的电力电子设备。这些项目的共同点很朴素——风机成本占比很小,却直接决定设备能否正常运行,值得与被保护设备同等的工程重视。
在最近一个改造项目中,客户的散热机组必须在更换磨损风机的同时保持运行。我们找到了安装尺寸完全相同、风量-压力曲线相当的在产替换型号,并确认了测速输出兼容性,整个安装在一个维护窗口内完成。
第二类高频场景来自制冷维修:冷凝器或蒸发器风机损坏,而原装型号交期漫长。不必等待——我们核对轴承类型、IP 防护等级、叶轮直径和转速,立即提供能恢复制冷量的等效型号。这正是我们的现货库存保护冷链运行的常见方式之一。
新造设备与替换项目都遵循同一路径:您提供所需的风量、压力和尺寸,我们回复入围清单、性能曲线和确定的交货日期。
可以。备件替换供应是我们的核心服务之一:我们会逐一核对您在用机组的安装尺寸、电压、转速和性能曲线,提出最接近的在产系列等效型号。如机壳或接口略有差异,我们会在下单前明确告知差异,确保替换安装不出现意外。
欢迎单件订购和样品申请——许多客户都会先在系统中验证一台样机,再决定批量采购。标准现货型号不设最低起订量,且多数复购订单可在批量货款中抵扣样品费。请告诉我们计划使用的数量,我们将同时给出两种方案的报价。
可以。除标准目录型号外,我们可以洽谈修改引线、接口、调速曲线、IP 防护升级或 OEM 贴牌包装等方案。定制通常从约定的年用量起步;我们的工程师会先评审您的需求,并在任何承诺之前确认可行性、模具费用和交期。
袋装
袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。