制造商料号 Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
9LG0624P4S001 | Sanyo Denki 24VDC 8.16W DC Axial Fan for telecommunications equipment cooling

For thermal management in servers, UPS systems, and telecom equipment, the 9LG0624P4S001 provides a 24 VDC DC axial fan configuration measuring 60 × 60 × 25 mm. 11000 rpm is the model's most prominent operating value. Review its supply requirement during controller selection. Check the full suffix before confirming connector details.

24 60*60*25 84 300 8.16 11000 53
9LG0824P4G001 | Sanyo Denki 24VDC 3.36W DC Axial Fan for telecommunications equipment cooling

Sanyo Denki configures 9LG0824P4G001 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 80 × 80 × 25 mm dimensions. A listed input of 3.36 W is the notable efficiency-related parameter. The recorded motor input should guide thermal validation. Confirm environmental protection for the ordered version.

24 80*80*25 92.31 97.1 3.36 5500 43
9LB1424S5J80 | Sanyo Denki 24VDC DC Axial Fan for telecommunications equipment cooling

Sanyo Denki configures 9LB1424S5J80 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 140 × 140 × 51 mm dimensions. The 140 × 140 × 51 mm format is the primary stated selection detail. Review its system interface during replacement evaluation. Treat bearing and life data as suffix-specific.

24 140*140*51 - - - - -
9LB1412S5D01 | Sanyo Denki 12VDC 32.4W DC Axial Fan for telecommunications equipment cooling

Designed for servers, UPS systems, and telecom equipment, Sanyo Denki 9LB1412S5D01 is a 12 VDC DC axial fan in a 140 × 140 × 51 mm frame. Its listed airflow of 480.6 m³/h is the standout performance value. Long-life series construction is the main characteristic stated in the supplied reference. Focus: equipment integration review motor input.

12 140*140*51 480.6 239.1 32.4 4200 57
9LG0424P3G001 | Sanyo Denki 24VDC 22.8W DC Axial Fan for telecommunications equipment cooling

The 40×40×28 mm Sanyo Denki 9LG0424P3G001 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. Base equipment integration on the stated cooling specification. Match the exact part number before approving a substitute.

24 40×40×28 55.8 1780 22.8 33500 68
9LG1224P1G001 | Sanyo Denki 24VDC 38.4W DC Axial Fan for telecommunications equipment cooling

Within telecom and network equipment, Sanyo Denki 9LG1224P1G001 operates as a 119 × 119 × 38 mm DC axial fan at 24 VDC. No exact entry appears in the supplied feature table, so bearing, control, and protection details require datasheet confirmation. 38.4 W input is the defining electrical-load figure. Focus: service access planning motor input.

24 119*119*38 419.9 368.7 38.4 6550 62
9LB1424S5D01 | Sanyo Denki 24VDC DC Axial Fan for telecommunications equipment cooling

The 9LB1424S5D01 is a Sanyo Denki 24 VDC, 140 × 140 × 51 mm DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. Base spares assessment on the stated pressure capability. Validate mounting and wiring from the model drawing.

24 140*140*51 486.2 - - 4200 57
9LB1424H5H03 | Sanyo Denki 24VDC 15.12W DC Axial Fan for telecommunications equipment cooling

The 9LB1424H5H03 is a Sanyo Denki 24 VDC, 140 × 140 × 50 mm DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. For equipment integration, start with the supplied selection parameters. Check the full suffix before confirming connector details.

24 140*140*50 23.8 - 15.12 3800 -
MFC0251V3-0000-A99 | SUNON 12V 1.68W 120x120x25mm 127.4m3/h DC Axial Fan for Telecommunications

The MFC0251V3-0000-A99 is SUNON's 12 VDC, 120 × 120 × 25 mm DC axial fan option for telecom cabinets and network equipment. Its 2200 rpm rating defines a lower-speed operating point. During cabinet ventilation planning, compare the model's mounting size. Verify bearing and signal options in the exact datasheet.

12 120x120x25mm 127.4 39.9 1.68 2200 34
MFC0251V2-0000-A99 | SUNON 12V 3W 120x120x25mm 158m3/h DC Axial Fan for Telecommunications

The 12 VDC SUNON MFC0251V2-0000-A99 is a DC axial fan sized 120 × 120 × 25 mm for telecom cabinets and network equipment. Its 2700 rpm rating defines a lower-speed operating point. The recorded supply requirement should guide cabinet ventilation planning. Verify bearing and signal options in the exact datasheet.

12 120x120x25mm 158 54.8 3 2700 40.5
MFC0251V1-0000-A99 | SUNON 12V 4.2W 120x120x25mm 183.8m3/h DC Axial Fan for Telecommunications

SUNON MFC0251V1-0000-A99 combines a 120 × 120 × 25 mm DC axial fan platform with a 12 VDC rating for telecom cabinets and network equipment. Up to 183.8 m³/h is its most prominent listed performance figure. For cabinet ventilation planning, start with the supplied static-pressure entry. Verify bearing and signal options in the exact datasheet.

12 120x120x25mm 183.8 69.7 4.2 3100 44.5
MF92252V3-10000-A99 | SUNON 24V 1.01W 92x92x25mm 67.1m3/h DC Axial Fan for Telecommunications

Engineered for telecom cabinets and network equipment, SUNON MF92252V3-10000-A99 is a 24 VDC DC axial fan in a 92 × 92 × 25 mm frame. Its 2400 rpm rating defines a lower-speed operating point. Use the documented volume-flow figure when planning cabinet ventilation planning. Verify bearing and signal options in the exact datasheet.

24 92x92x25mm 67.1 24.9 1.01 2400 28
MF92252V2-10000-A99 | SUNON 24V 1.32W 92x92x25mm 76.5m3/h DC Axial Fan for Telecommunications

Within telecom cabinets and network equipment, SUNON MF92252V2-10000-A99 serves as a 92 × 92 × 25 mm DC axial fan operating at 24 VDC. Its 2700 rpm rating defines a lower-speed operating point. Review its sound level during cabinet ventilation planning. Verify bearing and signal options in the exact datasheet.

24 92x92x25mm 76.5 32.4 1.32 2700 32
MF92252V1-10000-A99 | SUNON 24V 1.8W 92x92x25mm 87.5m3/h DC Axial Fan for Telecommunications

Specified at 24 VDC, MF92252V1-10000-A99 is a SUNON DC axial fan for telecom cabinets and network equipment in 92 × 92 × 25 mm dimensions. Its 3000 rpm rating defines a lower-speed operating point. Treat the rotational rating as a primary input to cabinet ventilation planning. Verify bearing and signal options in the exact datasheet.

24 92x92x25mm 87.5 37.4 1.8 3000 34
MF92251V3-10000-A99 | SUNON 12V 0.9W 92x92x25mm 67.1m3/h DC Axial Fan for Telecommunications

The MF92251V3-10000-A99 is SUNON's 12 VDC, 92 × 92 × 25 mm DC axial fan option for telecom cabinets and network equipment. Its 2400 rpm rating defines a lower-speed operating point. Base cabinet ventilation planning on the stated power demand. Verify bearing and signal options in the exact datasheet.

12 92x92x25mm 67.1 24.9 0.9 2400 28
MF92251V2-10000-A99 | SUNON 12V 1.26W 92x92x25mm 76.5m3/h DC Axial Fan for Telecommunications

Built for telecom cabinets and network equipment, SUNON MF92251V2-10000-A99 uses a 92 × 92 × 25 mm DC axial fan arrangement at 12 VDC. Its 2700 rpm rating defines a lower-speed operating point. During cabinet ventilation planning, compare the model's frame geometry. Verify bearing and signal options in the exact datasheet.

12 92x92x25mm 76.5 32.4 1.26 2700 32
MF92251V1-10000-A99 | SUNON 12V 1.68W 92x92x25mm 87.5m3/h DC Axial Fan for Telecommunications

SUNON MF92251V1-10000-A99 combines a 92 × 92 × 25 mm DC axial fan platform with a 12 VDC rating for telecom cabinets and network equipment. Its 3000 rpm rating defines a lower-speed operating point. The recorded cooling output should guide cabinet ventilation planning. Verify bearing and signal options in the exact datasheet.

12 92x92x25mm 87.5 37.4 1.68 3000 34
MF80252V3-10000-A99 | SUNON 24V 0.96W 80x80x25mm 56.1m3/h DC Axial Fan for Telecommunications

Sized for telecom cabinets and network equipment, SUNON MF80252V3-10000-A99 is a 24 VDC DC axial fan in a 80 × 80 × 25 mm frame. Its 2600 rpm rating defines a lower-speed operating point. For cabinet ventilation planning, start with the supplied operating point. Verify bearing and signal options in the exact datasheet.

24 80x80x25mm 56.1 27.4 0.96 2600 28
MF80252V2-10000-A99 | SUNON 24V 1.2W 80x80x25mm 62.9m3/h DC Axial Fan for Telecommunications

Within telecom cabinets and network equipment, SUNON MF80252V2-10000-A99 serves as a 80 × 80 × 25 mm DC axial fan operating at 24 VDC. Its 2900 rpm rating defines a lower-speed operating point. Use the documented pressure capability when planning cabinet ventilation planning. Verify bearing and signal options in the exact datasheet.

24 80x80x25mm 62.9 37.4 1.2 2900 30
MF80252V1-10000-A99 | SUNON 24V 1.56W 80x80x25mm 69.7m3/h DC Axial Fan for Telecommunications

Within telecom cabinets and network equipment, MF80252V1-10000-A99 provides a 80 × 80 × 25 mm, 24 VDC DC axial fan configuration. Its 3200 rpm rating defines a lower-speed operating point. Review its dimensional envelope during cabinet ventilation planning. Verify bearing and signal options in the exact datasheet.

24 80x80x25mm 69.7 44.8 1.56 3200 33
显示
1-20
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-301
共 301 个
1 2 3 4 5 6 7 8 9 10 ... 15 16
跳转 页

关于电信

如何选择合适的电信

选择合适的电信,应从工作点出发而不是从型号名称出发。先确定您实际需要的风量(CFM 或 m³/h)以及风机需要克服的静压,再寻找性能曲线能以一定裕量穿过该工作点的机型,而不是刚好压在曲线边缘的产品。

电气细节要尽早确认。DC 风机通常采用 12/24/48 V 供电,易于与控制板集成;AC 风机适合 115/230 V 定速安装场合。如果风量需要随负载变化,请选择支持 PWM 或模拟量控制的 EC 技术;在需要状态监控的场合,测速输出可以让控制器及时发现风机故障。

下一步是环境与认证。根据粉尘和潮湿暴露程度匹配 IP 防护等级,凡在高温、立式或全天候连续运行的场合,优先选择滚珠轴承,并对照目标市场确认 UL、CE、RoHS 等认证。尽早以 dBA 设定声学限值,可以避免第一台样机噪声过大时的后期返工。

最后,请从整体供货风险而非单纯价格来比较候选型号:确认所需数量的现货情况,核实后续批次的交期,并在确认前索取规格书和尺寸图。报价前,我们的团队会为您交叉核对曲线、尺寸和电气参数 该分类目前有 301 件产品可供对比。

电信的典型应用场景与案例

电信几乎出现在所有需要可靠排热或换气的行业。典型环境包括机房与数据中心、制冷冷凝器与冷库蒸发器、暖通空调组合式空调机组、通信机柜、医疗与实验室设备、焊接与数控机床机壳,以及新能源电力柜。在这些场景中,风机都是关键部件:一旦故障就意味着停产、货物受损或代价高昂的紧急停机。

一个反复出现的场景来自控制柜改造:原装风机已停产,安装孔位不能改动,停机时间以小时计。我们按机壳尺寸、风量和噪音将旧型号与在产系列逐一比对,提出最接近的直接替换方案,并随货附上规格书,让电工无需重新设计即可接线。

对冷库运营方来说,痛点很直接:蒸发器或冷凝器风机故障必须立即更换,而不是等六周的进口周期。将叶轮直径、转速和防护等级与现货等效型号逐一比对,我们能在几天内恢复制冷能力——备件替换供应也因此成为我们在该分类下的核心业务。

无论您是在制造新设备还是维护既有设备,流程都一样:把工作点和约束条件发给我们,我们回报经过验证的选型结果,并附规格书、性能曲线和明确的交期。

电信采购常见问题解答

电信是否有现货?多久可以发货?

常规系列和主流电压版本通常备有现货,可在几个工作日内发货;特殊或定制版本按订单生产,一般需要额外的生产时间。您只需提供确切型号或所需参数,我们将在一次回复中确认库存、单价和最早发货日期,该分类目前在线展示 301 件产品。

能否替换我在用的其他供应商的电信或已停产的型号?

可以。备件替换供应是我们的核心服务之一:我们会逐一核对您在用机组的安装尺寸、电压、转速和性能曲线,提出最接近的在产系列等效型号。如机壳或接口略有差异,我们会在下单前明确告知差异,确保替换安装不出现意外。

批量采购前可以单件下单或申请样品吗?

欢迎单件订购和样品申请——许多客户都会先在系统中验证一台样机,再决定批量采购。标准现货型号不设最低起订量,且多数复购订单可在批量货款中抵扣样品费。请告诉我们计划使用的数量,我们将同时给出两种方案的报价。

袋装

袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。