三洋电机株式会社是日本领先的高精度电机、风扇及泵制造商,产品广泛应用于工业和消费电子领域。三洋电机总部位于日本东京,拥有遍布全球的生产和分销网络,其生产的San Ace系列风扇以卓越的品质、可靠性和性能享誉全球。San Ace产品线包括用于电源和逆变器散热的交流轴流风扇、用于服务器和数据中心应用的直流轴流风扇,以及适用于恶劣工业环境的专用风扇。三洋电机的风扇采用了多项先进技术,包括PBT玻纤叶轮、用于延长使用寿命的密封滚珠轴承,以及用于智能热管理的PWM调速功能。恒瑞是三洋电机在中国的授权经销商,提供完整的San Ace系列风机产品组合,包括9GV系列高静压风机、109系列标准交流风机,以及最新款EC风机,并可享受具有竞争力的定价和原厂授权的技术支持。
| 制造商料号 | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() 9GA0912P4S03 | Sanyo Denki 12VDC 2.4W DC Axial Fan for UPS, server and telecom equipment cooling The 9GA0912P4S03 is a Sanyo Denki 12 VDC, 92 × 92 × 25 mm DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. The recorded operating point should guide duty-point matching. Confirm control inputs against the complete ordering code. |
12 | 92*92*25 | 100 | 60.6 | 2.4 | 3800 | 35 | |
![]() 109BC24GC7-1 | Sanyo Denki 24VDC 1.68W DC Centrifugal Blower for medical equipment cooling Sanyo Denki 109BC24GC7-1 combines a 52 × 52 × 15 mm DC blower platform with a 24 VDC rating for medical equipment cooling. The series cooling function is confirmed; suffix-specific options require datasheet verification. The 7.5 m³/h airflow figure supports its stated equipment-cooling role. Focus: spares strategy planning cooling specification. |
24 | 52*52*15 mm | 7.5 | 215 | 1.68 | 6200 | 43 | |
![]() 9WPA0424P3G001 | Sanyo Denki 24VDC 6W DC Axial Fan for solar inverter and energy storage cooling Sanyo Denki configures 9WPA0424P3G001 for outdoor equipment and photovoltaic inverters as a 24 VDC DC axial fan with 40 × 40 × 28 mm dimensions. 22200 rpm is the model's most prominent operating value. Review its thermal-duty record during cabinet ventilation planning. Validate mounting and wiring from the model drawing. |
24 | 40*40*28 | 37.74 | 553 | 6 | 22200 | 53 | |
![]() 9BMB24P2H01 | Sanyo Denki 24VDC 13.2W DC Centrifugal Blower for medical equipment cooling Sanyo Denki 9BMB24P2H01 is a 24 VDC DC blower in a 97 × 97 × 33 mm format for medical equipment cooling. Series options require suffix verification. 490 Pa maximum pressure is the most distinctive duty-point parameter. Check spares strategy planning installation footprint. Focus: spares strategy planning installation footprint. |
24 | 97*97*33 mm | 66.6 | 490 | 13.2 | 4850 | 57 | |
![]() 109R0624G401 | Sanyo Denki 24VDC 3.12W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki configures 109R0624G401 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 60 × 60 × 25 mm dimensions. The 46.2 m³/h airflow figure supports its stated equipment-cooling role. The recorded thermal-duty record should guide mounting verification. Verify the exact bearing and signal options in the datasheet. |
24 | 60*60*25 | 46.2 | 87.3 | 3.12 | 5600 | 39 | |
![]() 9BD12SC6-1 | Sanyo Denki 12VDC 3.36W DC Centrifugal Blower for medical equipment cooling The 76 × 76 × 20 mm Sanyo Denki 9BD12SC6-1 brings 12 VDC DC blower cooling to medical equipment cooling. Series options require suffix verification. Use the documented static-pressure entry when planning wiring review. Verify the exact bearing and signal options in the datasheet. Focus: spares strategy planning rated dataset. |
12 | 76*76*20 mm | 17.4 | 300 | 3.36 | 4500 | 43 | |
![]() 9LG0624P4S001 | Sanyo Denki 24VDC 8.16W DC Axial Fan for telecommunications equipment cooling For thermal management in servers, UPS systems, and telecom equipment, the 9LG0624P4S001 provides a 24 VDC DC axial fan configuration measuring 60 × 60 × 25 mm. 11000 rpm is the model's most prominent operating value. Review its supply requirement during controller selection. Check the full suffix before confirming connector details. |
24 | 60*60*25 | 84 | 300 | 8.16 | 11000 | 53 | |
![]() 9A0624H4D08 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling For servers, UPS systems, and telecom equipment, 9A0624H4D08 combines 24 VDC operation with a 60 × 60 × 25 mm DC axial fan design. High airflow is highlighted together with a high-static-pressure design. The 60 × 60 × 25 mm format is the primary stated selection detail. Check spares strategy planning ventilation capacity. |
24 | 60*60*25 | - | - | - | - | - | |
![]() 109P0424H302 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling The 40 × 40 × 28 mm Sanyo Denki 109P0424H302 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Treat the thermal-duty record as a primary input to power-budget planning. Validate mounting and wiring from the model drawing. Focus: spares strategy planning equipment fit. |
24 | 40*40*28 | - | - | - | 8700 | 37 | |
![]() 9CRA0612P6K001 | Sanyo Denki 12VDC 37.2W Counter-Rotating DC Axial Fan for data center and telecom cooling Within servers, UPS systems, and telecom equipment, Sanyo Denki 9CRA0612P6K001 operates as a 60 × 60 × 56 mm DC axial fan at 12 VDC. Series options require suffix verification. The supplied row lists 73 dB as an important acoustic selection value. Focus: spares strategy planning suffix definition. |
12 | 60*60*56 mm | 136.8 | 1130 | 37.2 | 18300 | 73 | |
![]() 9HV0824P1G003 | Sanyo Denki 24VDC 40.8W DC Axial Fan for AI servers and high-density equipment cooling Sanyo Denki configures 9HV0824P1G003 for AI servers and high-density electronics as a 24 VDC DC axial fan with 80 × 80 × 38 mm dimensions. The supplied row lists 69 dB as an important acoustic selection value. For enclosure sizing, start with the supplied ventilation capacity. Use the latest specification for frequency and tolerance limits. |
24 | 80*80*38 mm | 222 | 1000 | 40.8 | 14900 | 69 | |
![]() 9WL0612P4J001 | Sanyo Denki 12VDC 4.68W DC Axial Fan for solar inverter and energy storage cooling The 9WL0612P4J001 is a Sanyo Denki 12 VDC, 60 × 60 × 25 mm DC axial fan for outdoor equipment and photovoltaic inverters. Its oil-resistant fan design and IP68 listing is the defining supplied feature. Use the documented electrical load when planning replacement evaluation. Validate mounting and wiring from the model drawing. |
12 | 60*60*25 mm | 66 | 182 | 4.68 | 8650 | 47 | |
![]() 9A0824S401 | Sanyo Denki 24VDC 2.4W DC Axial Fan for UPS, server and telecom equipment cooling Within servers, UPS systems, and telecom equipment, 9A0824S401 provides a 80 × 80 × 25 mm, 24 VDC DC axial fan configuration. High airflow is highlighted together with a high-static-pressure design. 48.1 Pa maximum pressure is the most distinctive duty-point parameter. Check spares strategy planning performance curve. |
24 | 80*80*25 | 71.4 | 48.1 | 2.4 | 3400 | 34 | |
![]() 9A0812H401 | Sanyo Denki 12VDC 1.56W DC Axial Fan for UPS, server and telecom equipment cooling Within servers, UPS systems, and telecom equipment, 9A0812H401 provides a 80 × 80 × 25 mm, 12 VDC DC axial fan configuration. High airflow is highlighted together with a high-static-pressure design. A listed input of 1.56 W is the notable efficiency-related parameter. Check spares strategy planning mounting size. Focus: spares strategy planning. |
12 | 80*80*25 | 61.2 | 35.4 | 1.56 | 2900 | 29 | |
![]() 109P0624S702 | Sanyo Denki 24VDC 1.92W DC Axial Fan for UPS, server and telecom equipment cooling For servers, UPS systems, and telecom equipment, 109P0624S702 combines 24 VDC operation with a 60 × 60 × 15 mm DC axial fan design. High airflow is highlighted together with a high-static-pressure design. The 28.4 m³/h airflow figure supports its stated equipment-cooling role. Check spares strategy planning supply requirement. |
24 | 60*60*15 | 28.4 | 58.8 | 1.92 | 5000 | 36 | |
![]() 109P0612H602 | Sanyo Denki 12VDC 1.56W DC Axial Fan for UPS, server and telecom equipment cooling A 60 × 60 × 20 mm frame and 12 VDC rating define 109P0612H602, a DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. 31.8 Pa maximum pressure is the most distinctive duty-point parameter. Check spares strategy planning static-pressure entry. Focus: spares strategy planning static-pressure entry. |
12 | 60*60*20 | 24.8 | 31.8 | 1.56 | 4200 | 31 | |
![]() 9S1224M4011 | Sanyo Denki 24VDC 1.44W DC Axial Fan for UPS, server and telecom equipment cooling Equipment designers serving servers, UPS systems, and telecom equipment can evaluate Sanyo Denki 9S1224M4011, a DC axial fan rated at 24 VDC and sized 120 × 120 × 25 mm. Its 1850 rpm rating defines a lower-speed operating point. The recorded duty-point values should guide spares assessment. Match the exact part number before approving a substitute. |
24 | 120*120*25 mm | 99.6 | 22.7 | 1.44 | 1850 | 24 | |
![]() 9GA0812P1G61 | Sanyo Denki 12VDC 14.4W DC Axial Fan for UPS, server and telecom equipment cooling A 80 × 80 × 38 mm frame and 12 VDC rating define 9GA0812P1G61, a DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. 480 Pa maximum pressure is the most distinctive duty-point parameter. Selection focus: spares strategy planning sound level. |
12 | 80*80*38 mm | 171 | 480 | 14.4 | 10500 | 60 | |
![]() 9GA0924P4J03 | Sanyo Denki 24VDC 4.8W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki 9GA0924P4J03 combines a 92 × 92 × 25 mm DC axial fan platform with a 24 VDC rating for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. Its listed airflow of 132.09 m³/h is the standout performance value. Focus: spares strategy planning. |
24 | 92*92*25 | 132.09 | 104.6 | 4.8 | 5000 | 43 | |
![]() 9GA0824P4G001 | Sanyo Denki 24VDC 5.04W DC Axial Fan for UPS, server and telecom equipment cooling For thermal management in servers, UPS systems, and telecom equipment, the 9GA0824P4G001 provides a 24 VDC DC axial fan configuration measuring 80 × 80 × 25 mm. 6800 rpm is the model's most prominent operating value. The recorded power demand should guide replacement evaluation. Validate mounting and wiring from the model drawing. |
24 | 80*80*25 | 115 | 150 | 5.04 | 6800 | 45 |
多年以来,我们的团队一直是值得信赖的 三洋 风机与鼓风机供应商,从初步选型到长期备件供应,持续为工程师和采购团队提供支持。
我们的客户将这类产品广泛应用于HVAC 暖通空调与通风、制冷与冷链设备、数据中心散热、工业过程冷却、电子与通信机柜热管理、新能源与电力设备。由于我们每天都在接触该品牌的产品,能够快速确认货源、对比参数曲线,并针对您的工作点推荐最具性价比的系列。
我们同时承接大量替换改造项目。如果您在用的 三洋 设备已经停产,我们的工程师会核对安装尺寸、电压和风量-压力曲线,在您确认下单前找出最接近的在产系列替代型号,并明确更换细节。
每一单 三洋 询价都有完整的工程技术支持作后盾——下单前提供规格书、性能曲线和尺寸图,数量从样品到批量灵活安排,设备整个使用周期内均可获得售后协助。
确定三洋最可靠的方法是从系统出发,而不是从产品目录出发。先实测或计算风量和压力需求,再加上安装位置的尺寸限制,最后才从曲线能以裕量覆盖您工作点的系列中筛选。
电气匹配是下一道关口。确认供电电压——小型电子散热常用 12 V、24 V 或 48 V DC,设备和机柜散热常用 115 V 或 230 V AC——并确定是否需要调速。EC 风机支持 PWM 或 0-10 V 信号调速,并可通过测速输出反馈转速,是变风量系统的默认之选;AC 风机在定速工况下则依然是高性价比方案。
接下来按环境筛选。高温环境、粉尘或潮湿负载决定了 IP 防护等级和轴承选择——滚珠轴承能让风量和噪音多年保持稳定,含油轴承则适合轻载卧式安装。UL、CE、RoHS 等法规认证要求应在入围名单提交采购前确认,同时确定允许的最大声压级(dBA)。
流程的最后是确认供应而不只是确认参数:确认当前库存和补货交期,取得规格书和尺寸图,确保机械接口在下单前验证完毕。把风量和压力需求发给我们,工程师将为您确认匹配度最高的系列 —— 该分类今天共有 579 件产品可供选购。
我们销售工程师的日常工作围绕三洋展开:数据中心散热、制冷与冷链项目、建筑通风、通信基站、医疗设备和工业控制柜——在这些环境中,风机停转就意味着业务停摆。正是这种对真实安装场景的日常积累,让我们在每一次选型中不只会看曲线,更清楚哪些型号能经受粉尘、高温、连续运行和维护空间受限的考验。
一个典型案例:某设备制造商需要更换控制柜内一台老旧 AC 风机,且柜体停机时间不能超过一小时。通过逐一核对机壳尺寸、电压和风量曲线,我们提供了带匹配测速信号的在产系列直接替换型号,更换工作在一个计划维护窗口内完成。
制冷与冷链客户带来另一种典型情况:损坏的冷凝器风机数周内无法到货。通过比对直径、转速、轴承和 IP 防护等级,我们从现货提供功能等效的机组,让系统当周恢复运行——这也是众多维修服务公司保存我们联系方式的原因。
从单件紧急替换到面向设备制造商的批量供应,每一单 三洋 询价我们都遵循同一原则:先核实参数,再报价——确保送到现场的就是项目真正需要的那台风机。
下单前可按需提供规格书、性能曲线、尺寸图和认证文件(视适用情况提供 UL、CE、RoHS)——我们始终认为,采购订单应建立在经过验证的选型之上,而不是取代选型。对于项目投标,我们还可以提供产品对比表,把候选型号按您关注的参数逐项并列呈现。
常规系列和主流电压版本通常备有现货,可在几个工作日内发货;特殊或定制版本按订单生产,一般需要额外的生产时间。您只需提供确切型号或所需参数,我们将在一次回复中确认库存、单价和最早发货日期,该分类目前在线展示 579 件产品。
可以。备件替换供应是我们的核心服务之一:我们会逐一核对您在用机组的安装尺寸、电压、转速和性能曲线,提出最接近的在产系列等效型号。如机壳或接口略有差异,我们会在下单前明确告知差异,确保替换安装不出现意外。
袋装
袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。