SUNON是全球微型及工业散热风扇技术领域最知名的品牌之一。SUNON于1980年在台湾高雄成立,从一家小型电机制造商发展成为一家全球化企业,在台湾、中国和越南设有生产基地,为全球50多个国家的客户提供服务。SUNON的产品组合涵盖了完整热管理元件的全系列产品——从适用于智能手表和便携式电子设备的15毫米超小型风扇,到用于电信和数据中心应用的高性能200毫米工业轴流风机以及120毫米离心鼓风机。该公司拥有的专利VAPO轴承技术和磁悬浮(MAGLEV)电机设计,可实现超长使用寿命(平均无故障时间超过60,000小时),并具备超低噪音运行特性。恒瑞是SUNON在中国的授权经销商,提供SUNON全系列产品,包括ME系列轴流风机、PMD系列直流鼓风机,以及旗舰级MAGLEV系列,并可享受工厂直供价格、原厂质保及全球配送服务。
| 制造商料号 | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() PF60382BX-10000-A9H | SUNON 24V 27.12W 60x60x38mm 127.8m3/h DC Axial Fan for Data Center Cooling PF60382BX-10000-A9H serves servers and data-center electronics as a 60 × 60 × 38 mm DC axial fan rated at 24 VDC. 889.3 Pa maximum pressure is the standout documented duty-point value. Treat the static-pressure entry as a primary input to installation review. Obtain the applicable curve before final duty-point approval. |
24 | 60x60x38mm | 127.8 | 889.3 | 27.12 | 16500 | 67 | |
![]() PF60382B3-10000-A9H | SUNON 24V 3.24W 60x60x38mm 70.3m3/h DC Axial Fan for Data Center Cooling The PF60382B3-10000-A9H is SUNON's 24 VDC, 60 × 60 × 38 mm DC axial fan option for servers and data-center electronics. 171.9 Pa maximum pressure is the standout documented duty-point value. Base installation review on the stated volume-flow figure. Obtain the applicable curve before final duty-point approval. |
24 | 60x60x38mm | 70.3 | 171.9 | 3.24 | 7400 | 47 | |
![]() PF60382B2-10000-A9H | SUNON 24V 6.96W 60x60x38mm 96m3/h DC Axial Fan for Data Center Cooling SUNON PF60382B2-10000-A9H is a 24 VDC DC axial fan in a 60 × 60 × 38 mm format for servers and data-center electronics. 318.8 Pa maximum pressure is the standout documented duty-point value. During installation review, compare the model's sound level. Obtain the applicable curve before final duty-point approval. |
24 | 60x60x38mm | 96 | 318.8 | 6.96 | 10300 | 56 | |
![]() PF60382B1-10000-A9H | SUNON 24V 13.2W 60x60x38mm 103m3/h DC Axial Fan for Data Center Cooling SUNON PF60382B1-10000-A9H combines a 60 × 60 × 38 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. 572.9 Pa maximum pressure is the standout documented duty-point value. The recorded rotational rating should guide installation review. Obtain the applicable curve before final duty-point approval. |
24 | 60x60x38mm | 103 | 572.9 | 13.2 | 13200 | 61.2 | |
![]() PF60381BX-10000-A9H | SUNON 12V 30W 60x60x38mm 127.8m3/h DC Axial Fan for Data Center Cooling Positioned for servers and data-center electronics, SUNON PF60381BX-10000-A9H is a 12 VDC DC axial fan in a 60 × 60 × 38 mm frame. 889.3 Pa maximum pressure is the standout documented duty-point value. For installation review, start with the supplied power demand. Obtain the applicable curve before final duty-point approval. |
12 | 60x60x38mm | 127.8 | 889.3 | 30 | 16500 | 67 | |
![]() PF60381B1-10000-A9H | SUNON 12V 14.4W 60x60x38mm 103m3/h DC Axial Fan for Data Center Cooling Within servers and data-center electronics, SUNON PF60381B1-10000-A9H serves as a 60 × 60 × 38 mm DC axial fan operating at 12 VDC. 572.9 Pa maximum pressure is the standout documented duty-point value. Use the documented frame geometry when planning installation review. Obtain the applicable curve before final duty-point approval. |
12 | 60x60x38mm | 103 | 572.9 | 14.4 | 13200 | 61.2 | |
![]() PF60252VX-10000-A99 | SUNON 24V 3.84W 60x60x25mm 68m3/h DC Axial Fan for Data Center Cooling Equipment designers working with servers and data-center electronics can evaluate SUNON PF60252VX-10000-A99, a DC axial fan rated at 24 VDC and sized 60 × 60 × 25 mm. 8300 rpm is the model's most distinctive operating parameter. Review its cooling output during installation review. Obtain the applicable curve before final duty-point approval. |
24 | 60x60x25mm | 68 | 164.4 | 3.84 | 8300 | 46 | |
![]() PF60252V3-10000-A99 | SUNON 24V 1.95W 60x60x25mm 49.3m3/h DC Axial Fan for Data Center Cooling The PF60252V3-10000-A99 is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. Treat the operating point as a primary input to installation review. Obtain the applicable curve before final duty-point approval. |
24 | 60x60x25mm | 49.3 | 102.1 | 1.95 | 6200 | 37.5 | |
![]() PF60252V2-10000-A99 | SUNON 24V 2.52W 60x60x25mm 53.5m3/h DC Axial Fan for Data Center Cooling SUNON configures PF60252V2-10000-A99 as a 60 × 60 × 25 mm DC axial fan for servers and data-center electronics, operating at 24 VDC. 124.5 Pa maximum pressure is the standout documented duty-point value. Base installation review on the stated pressure capability. Obtain the applicable curve before final duty-point approval. |
24 | 60x60x25mm | 53.5 | 124.5 | 2.52 | 7000 | 40.7 | |
![]() PF60252V1-10000-A99 | SUNON 24V 3.03W 60x60x25mm 61.2m3/h DC Axial Fan for Data Center Cooling SUNON PF60252V1-10000-A99 combines a 60 × 60 × 25 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. During installation review, compare the model's dimensional envelope. Obtain the applicable curve before final duty-point approval. |
24 | 60x60x25mm | 61.2 | 139.5 | 3.03 | 7500 | 41.7 | |
![]() PF60252BX-10000-A99 | SUNON 24V 3.22W 60x60x25mm 68m3/h 8300rpm DC Axial Fan for New Energy Built around inverters, energy-storage systems, and charging equipment, SUNON PF60252BX-10000-A99 is a 24 VDC DC axial fan in a 60 × 60 × 25 mm frame. 8300 rpm is the model's most distinctive operating parameter. The recorded acoustic value should guide installation review. Obtain the applicable curve before final duty-point approval. |
24 | 60x60x25mm | 68 | 164.4 | 3.22 | 8300 | 46 | |
![]() PF60252B3-10000-A99 | SUNON 24V 1.56W 60x60x25mm 49.3m3/h DC Axial Fan for Data Center Cooling Within servers and data-center electronics, SUNON PF60252B3-10000-A99 serves as a 60 × 60 × 25 mm DC axial fan operating at 24 VDC. 102.1 Pa maximum pressure is the standout documented duty-point value. For installation review, start with the supplied electrical load. Obtain the applicable curve before final duty-point approval. |
24 | 60x60x25mm | 49.3 | 102.1 | 1.56 | 6200 | 37.5 | |
![]() PF60252B2-10000-A99 | SUNON 24V 2.14W 60x60x25mm 53.5m3/h DC Axial Fan for Data Center Cooling For servers and data-center electronics, PF60252B2-10000-A99 combines 24 VDC operation with a 60 × 60 × 25 mm DC axial fan design. 124.5 Pa maximum pressure is the standout documented duty-point value. Use the documented speed benchmark when planning installation review. Obtain the applicable curve before final duty-point approval. |
24 | 60x60x25mm | 53.5 | 124.5 | 2.14 | 7000 | 40.7 | |
![]() PF60252B1-10000-A99 | SUNON 24V 2.57W 60x60x25mm 61.2m3/h DC Axial Fan for Data Center Cooling The PF60252B1-10000-A99 is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Review its airflow profile during installation review. Obtain the applicable curve before final duty-point approval. |
24 | 60x60x25mm | 61.2 | 139.5 | 2.57 | 7500 | 41.7 | |
![]() PF60251VX-10000-A99 | SUNON 12V 4.08W 60x60x25mm 68m3/h DC Axial Fan for Data Center Cooling For ventilation needs in servers and data-center electronics, the PF60251VX-10000-A99 provides a 12 VDC DC axial fan configuration measuring 60 × 60 × 25 mm. 8300 rpm is the model's most distinctive operating parameter. Treat the application data as a primary input to design qualification. Match the exact part number before approving a substitute. |
12 | 60x60x25mm | 68 | 164.4 | 4.08 | 8300 | 46 | |
![]() PF60251V3-10000-A99 | SUNON 12V 1.92W 60x60x25mm 49.3m3/h DC Axial Fan for Data Center Cooling SUNON PF60251V3-10000-A99 combines a 60 × 60 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. Base design qualification on the stated technical profile. Match the exact part number before approving a substitute. |
12 | 60x60x25mm | 49.3 | 102.1 | 1.92 | 6200 | 37.5 | |
![]() PF60251V2-10000-A99 | SUNON 12V 2.58W 60x60x25mm 53.5m3/h DC Axial Fan for Data Center Cooling Configured for servers and data-center electronics, SUNON PF60251V2-10000-A99 is a 12 VDC DC axial fan in a 60 × 60 × 25 mm frame. 124.5 Pa maximum pressure is the standout documented duty-point value. During design qualification, compare the model's model record. Match the exact part number before approving a substitute. |
12 | 60x60x25mm | 53.5 | 124.5 | 2.58 | 7000 | 40.7 | |
![]() PF60251V1-10000-A99 | SUNON 12V 3.1W 60x60x25mm 61.2m3/h DC Axial Fan for Data Center Cooling Within servers and data-center electronics, SUNON PF60251V1-10000-A99 serves as a 60 × 60 × 25 mm DC axial fan operating at 12 VDC. 139.5 Pa maximum pressure is the standout documented duty-point value. The recorded product configuration should guide design qualification. Match the exact part number before approving a substitute. |
12 | 60x60x25mm | 61.2 | 139.5 | 3.1 | 7500 | 41.7 | |
![]() PF60251BX-10000-A99 | SUNON 12V 3.24W 60x60x25mm 68m3/h DC Axial Fan for Data Center Cooling A 60 × 60 × 25 mm frame and 12 VDC rating define PF60251BX-10000-A99, a DC axial fan for servers and data-center electronics. 8300 rpm is the model's most distinctive operating parameter. For design qualification, start with the supplied system interface. Match the exact part number before approving a substitute. |
12 | 60x60x25mm | 68 | 164.4 | 3.24 | 8300 | 46 | |
![]() PF60251B3-10000-A99 | SUNON 12V 1.42W 60x60x25mm 49.3m3/h DC Axial Fan for Data Center Cooling The PF60251B3-10000-A99 is SUNON's 12 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. Use the documented cooling specification when planning design qualification. Match the exact part number before approving a substitute. |
12 | 60x60x25mm | 49.3 | 102.1 | 1.42 | 6200 | 37.5 |
我们是一家专注于 SUNON 产品的工业风机与鼓风机供应商,超过 20 年来一直帮助客户针对每一个应用场景正确选型、采购和维护。
应用领域覆盖HVAC 暖通空调与通风、制冷与冷链设备、数据中心散热、工业过程冷却、电子与通信机柜热管理、新能源与电力设备。常用型号我们备有现货,每一条选型建议都附带规格书、尺寸图和性能曲线,方便您在下单前完成选型验证。
除新品供应外,我们还积累了大量替换改造项目经验:当原装 SUNON 型号停产或交期过长时,我们会逐一核对安装尺寸、电气参数和性能曲线,提出无需改动机械结构与接线的兼容替代方案。
我们的服务覆盖设备整个生命周期:售前选型支持、供工程审核的完整规格书与尺寸图、从一个样品到批量供货的弹性数量,以及 SUNON 设备在用期间随时可响应的售后协助。
在对比SUNON的型号之前,先列明真实的运行需求:所需风量、系统静压、可用安装空间和现场供电条件。忽略这四项因素中任何一项的选型,通常最终都会以退货或现场改造收场。
电压和控制方式决定入围范围。标准选项包括 12/24/48 V DC 和 115/230 V AC;对于工作点会变化的场合,支持 PWM 或 0-10 V 输入的 EC 风机可实现精准调速,测速信号则能提供许多安全系统所需的反馈。
环境条件比任何目录筛选器都更快地淘汰不合适的型号。检查环境温度范围、防尘防潮所需的 IP 防护等级以及预期使用寿命——在立式安装或高温位置,滚珠轴承机型保持噪音和风量指标稳定的时间远长于含油轴承设计。如果设备要销往受监管市场,应在此阶段确认 UL、CE 和 RoHS 认证,并尽早设定以 dBA 为单位的噪音目标,避免声学问题在安装后才暴露。
收尾阶段要为订单排除风险:核实库存水平,确认生产交期,并索取候选型号的规格书和尺寸图,确保安装孔位和接口在采购前核对无误。把您的工作点提供给我们,我们将验证匹配性 该分类现有 1,066 件产品可随时对比。
从我们的项目记录看,凡是设备需要持续散热、空气需要持续流动的场合都会用到SUNON:数据中心与机房、商用制冷、空调通风系统、通信与电池柜、工业机械设备,以及新能源领域的电力电子设备。这些项目的共同点很朴素——风机成本占比很小,却直接决定设备能否正常运行,值得与被保护设备同等的工程重视。
在最近一个改造项目中,客户的散热机组必须在更换磨损风机的同时保持运行。我们找到了安装尺寸完全相同、风量-压力曲线相当的在产替换型号,并确认了测速输出兼容性,整个安装在一个维护窗口内完成。
第二类高频场景来自制冷维修:冷凝器或蒸发器风机损坏,而原装型号交期漫长。不必等待——我们核对轴承类型、IP 防护等级、叶轮直径和转速,立即提供能恢复制冷量的等效型号。这正是我们的现货库存保护冷链运行的常见方式之一。
无论新造设备还是 SUNON 设备的替换项目,在我们这里都遵循同一路径:您提供所需的风量、压力和尺寸,我们回复入围清单、性能曲线和确定的交货日期。
每台机组均享受制造商针对材料和工艺缺陷的质保,索赔全程由我们协助处理,您只需对接一家供应商,无需跨国追查工厂。如在使用中出现故障,请提供序列号、运行工况和照片,我们将按报价约定的方式安排更换或退款。
下单前可按需提供规格书、性能曲线、尺寸图和认证文件(视适用情况提供 UL、CE、RoHS)——我们始终认为,采购订单应建立在经过验证的选型之上,而不是取代选型。对于项目投标,我们还可以提供产品对比表,把候选型号按您关注的参数逐项并列呈现。
常规系列和主流电压版本通常备有现货,可在几个工作日内发货;特殊或定制版本按订单生产,一般需要额外的生产时间。您只需提供确切型号或所需参数,我们将在一次回复中确认库存、单价和最早发货日期,该分类目前在线展示 1,066 件产品。
袋装
袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。