SUNON是全球微型及工业散热风扇技术领域最知名的品牌之一。SUNON于1980年在台湾高雄成立,从一家小型电机制造商发展成为一家全球化企业,在台湾、中国和越南设有生产基地,为全球50多个国家的客户提供服务。SUNON的产品组合涵盖了完整热管理元件的全系列产品——从适用于智能手表和便携式电子设备的15毫米超小型风扇,到用于电信和数据中心应用的高性能200毫米工业轴流风机以及120毫米离心鼓风机。该公司拥有的专利VAPO轴承技术和磁悬浮(MAGLEV)电机设计,可实现超长使用寿命(平均无故障时间超过60,000小时),并具备超低噪音运行特性。恒瑞是SUNON在中国的授权经销商,提供SUNON全系列产品,包括ME系列轴流风机、PMD系列直流鼓风机,以及旗舰级MAGLEV系列,并可享受工厂直供价格、原厂质保及全球配送服务。
| 制造商料号 | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() GF40282B3-10000-ADP | SUNON 24V 40x40x28mm 24m3/h 500rpm DC Axial Fan for Data Center Cooling SUNON configures GF40282B3-10000-ADP as a 40 × 40 × 28 mm DC axial fan for servers and data-center electronics, operating at 24 VDC. Its 500 rpm rating defines a lower-speed operating point. Treat the pressure capability as a primary input to cooling-margin review. Check the full suffix before confirming connector details. |
24 | 40x40x28mm | 24 | 176.9 | - | 500 | 45 | |
![]() GF40282B2-10000-SDP | SUNON 24V 13100W 40x40x28mm 31.1m3/h DC Axial Fan for Industrial Cooling SUNON GF40282B2-10000-SDP combines a 40 × 40 × 28 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. 13100 W input is the defining electrical load in the supplied data. Base cooling-margin review on the stated dimensional envelope. Check the full suffix before confirming connector details. |
24 | 40x40x28mm | 31.1 | 281.5 | 13100 | 13100 | 51.7 | |
![]() GF40282B2-10000-QDP | SUNON 24V 13100W 40x40x28mm 31.1m3/h DC Axial Fan for Industrial Cooling Applied in servers and data-center electronics, SUNON GF40282B2-10000-QDP is a 24 VDC DC axial fan in a 40 × 40 × 28 mm frame. 13100 W input is the defining electrical load in the supplied data. During cooling-margin review, compare the model's acoustic value. Check the full suffix before confirming connector details. |
24 | 40x40x28mm | 31.1 | 281.5 | 13100 | 13100 | 51.7 | |
![]() GF40282B2-10000-AEP | SUNON 24V 40x40x28mm 30.1m3/h 3100rpm DC Axial Fan for Data Center Cooling Within servers and data-center electronics, SUNON GF40282B2-10000-AEP serves as a 40 × 40 × 28 mm DC axial fan operating at 24 VDC. 276.5 Pa maximum pressure is the standout documented duty-point value. The recorded electrical load should guide cooling-margin review. Check the full suffix before confirming connector details. |
24 | 40x40x28mm | 30.1 | 276.5 | - | 3100 | 50 | |
![]() GF40282B2-10000-ADP | SUNON 24V 40x40x28mm 30.1m3/h 3100rpm DC Axial Fan for Data Center Cooling For servers and data-center electronics, GF40282B2-10000-ADP combines 24 VDC operation with a 40 × 40 × 28 mm DC axial fan design. 276.5 Pa maximum pressure is the standout documented duty-point value. For cooling-margin review, start with the supplied speed benchmark. Check the full suffix before confirming connector details. |
24 | 40x40x28mm | 30.1 | 276.5 | - | 3100 | 50 | |
![]() GF40282B1-10000-SDP | SUNON 24V 14600W 40x40x28mm 34.7m3/h DC Axial Fan for Industrial Cooling The GF40282B1-10000-SDP is SUNON's 24 VDC, 40 × 40 × 28 mm DC axial fan option for servers and data-center electronics. 14600 W input is the defining electrical load in the supplied data. Use the documented airflow profile when planning cooling-margin review. Check the full suffix before confirming connector details. |
24 | 40x40x28mm | 34.7 | 351.2 | 14600 | 14600 | 54 | |
![]() GF40282B1-10000-QDP | SUNON 24V 14600W 40x40x28mm 34.7m3/h DC Axial Fan for Industrial Cooling For thermal management in servers and data-center electronics, the GF40282B1-10000-QDP provides a 24 VDC DC axial fan configuration measuring 40 × 40 × 28 mm. 14600 W input is the defining electrical load in the supplied data. Review its application data during cabinet ventilation planning. Verify bearing and signal options in the exact datasheet. |
24 | 40x40x28mm | 34.7 | 351.2 | 14600 | 14600 | 54 | |
![]() GF40282B1-10000-AEP | SUNON 24V 40x40x28mm 33.3m3/h 4600rpm DC Axial Fan for Data Center Cooling SUNON GF40282B1-10000-AEP combines a 40 × 40 × 28 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. 343.7 Pa maximum pressure is the standout documented duty-point value. Treat the technical profile as a primary input to cabinet ventilation planning. Verify bearing and signal options in the exact datasheet. |
24 | 40x40x28mm | 33.3 | 343.7 | - | 4600 | 52.8 | |
![]() GF40282B1-10000-ADP | SUNON 24V 40x40x28mm 33.3m3/h 4600rpm DC Axial Fan for Data Center Cooling Positioned for servers and data-center electronics, SUNON GF40282B1-10000-ADP is a 24 VDC DC axial fan in a 40 × 40 × 28 mm frame. 343.7 Pa maximum pressure is the standout documented duty-point value. Base cabinet ventilation planning on the stated model record. Verify bearing and signal options in the exact datasheet. |
24 | 40x40x28mm | 33.3 | 343.7 | - | 4600 | 52.8 | |
![]() GF92252B7-0000-AD9 | SUNON 24V 1.13W 92x92x25mm 67.1m3/h DC Axial Fan for Data Center Cooling Within servers and data-center electronics, SUNON GF92252B7-0000-AD9 serves as a 92 × 92 × 25 mm DC axial fan operating at 24 VDC. Its 2400 rpm rating defines a lower-speed operating point. During cabinet ventilation planning, compare the model's product configuration. Verify bearing and signal options in the exact datasheet. |
24 | 92x92x25mm | 67.1 | 24.9 | 1.13 | 2400 | 28 | |
![]() GF92252B6-0000-AD9 | SUNON 24V 1.56W 92x92x25mm 76.5m3/h DC Axial Fan for Data Center Cooling A 92 × 92 × 25 mm frame and 24 VDC rating define GF92252B6-0000-AD9, a DC axial fan for servers and data-center electronics. Its 2700 rpm rating defines a lower-speed operating point. The recorded system interface should guide cabinet ventilation planning. Verify bearing and signal options in the exact datasheet. |
24 | 92x92x25mm | 76.5 | 32.4 | 1.56 | 2700 | 32 | |
![]() GF92252B5-0000-AD9 | SUNON 24V 2.09W 92x92x25mm 87.5m3/h DC Axial Fan for Data Center Cooling The GF92252B5-0000-AD9 is SUNON's 24 VDC, 92 × 92 × 25 mm DC axial fan option for servers and data-center electronics. Its 3000 rpm rating defines a lower-speed operating point. For cabinet ventilation planning, start with the supplied cooling specification. Verify bearing and signal options in the exact datasheet. |
24 | 92x92x25mm | 87.5 | 37.4 | 2.09 | 3000 | 34 | |
![]() GF92251B7-0000-AD9 | SUNON 12V 1.1W 92x92x25mm 67.1m3/h DC Axial Fan for Data Center Cooling Within servers and data-center electronics, GF92251B7-0000-AD9 provides a 92 × 92 × 25 mm, 12 VDC DC axial fan configuration. Its 2400 rpm rating defines a lower-speed operating point. Use the documented duty-point values when planning cabinet ventilation planning. Verify bearing and signal options in the exact datasheet. |
12 | 92x92x25mm | 67.1 | 24.9 | 1.1 | 2400 | 28 | |
![]() GF92251B6-0000-AD9 | SUNON 12V 1.62W 92x92x25mm 76.5m3/h DC Axial Fan for Data Center Cooling SUNON GF92251B6-0000-AD9 combines a 92 × 92 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. Its 2700 rpm rating defines a lower-speed operating point. Review its installation footprint during cabinet ventilation planning. Verify bearing and signal options in the exact datasheet. |
12 | 92x92x25mm | 76.5 | 32.4 | 1.62 | 2700 | 32 | |
![]() GF92251B5-0000-AD9 | SUNON 12V 1.98W 92x92x25mm 87.5m3/h DC Axial Fan for Data Center Cooling Built around servers and data-center electronics, SUNON GF92251B5-0000-AD9 is a 12 VDC DC axial fan in a 92 × 92 × 25 mm frame. Its 3000 rpm rating defines a lower-speed operating point. Treat the selection parameters as a primary input to cabinet ventilation planning. Verify bearing and signal options in the exact datasheet. |
12 | 92x92x25mm | 87.5 | 37.4 | 1.98 | 3000 | 34 | |
![]() GF80252B7-0000-AD9 | SUNON 24V 1.08W 80x80x25mm 56.1m3/h DC Axial Fan for Data Center Cooling Within servers and data-center electronics, SUNON GF80252B7-0000-AD9 serves as a 80 × 80 × 25 mm DC axial fan operating at 24 VDC. Its 2600 rpm rating defines a lower-speed operating point. Base cabinet ventilation planning on the stated rated dataset. Verify bearing and signal options in the exact datasheet. |
24 | 80x80x25mm | 56.1 | 27.4 | 1.08 | 2600 | 28 | |
![]() GF80252B6-0000-AD9 | SUNON 24V 1.42W 80x80x25mm 62.9m3/h DC Axial Fan for Data Center Cooling SUNON GF80252B6-0000-AD9 is a 24 VDC DC axial fan in a 80 × 80 × 25 mm format for servers and data-center electronics. Its 2900 rpm rating defines a lower-speed operating point. During cabinet ventilation planning, compare the model's motor input. Verify bearing and signal options in the exact datasheet. |
24 | 80x80x25mm | 62.9 | 37.4 | 1.42 | 2900 | 30 | |
![]() GF80252B5-0000-AD9 | SUNON 24V 1.76W 80x80x25mm 69.7m3/h DC Axial Fan for Data Center Cooling The GF80252B5-0000-AD9 is SUNON's 24 VDC, 80 × 80 × 25 mm DC axial fan option for servers and data-center electronics. Its 3200 rpm rating defines a lower-speed operating point. The recorded ventilation capacity should guide cabinet ventilation planning. Verify bearing and signal options in the exact datasheet. |
24 | 80x80x25mm | 69.7 | 44.8 | 1.76 | 3200 | 33 | |
![]() GF80251B7-0000-AD9 | SUNON 12V 1.01W 80x80x25mm 56.1m3/h DC Axial Fan for Data Center Cooling For ventilation needs in servers and data-center electronics, the GF80251B7-0000-AD9 provides a 12 VDC DC axial fan configuration measuring 80 × 80 × 25 mm. Its 2600 rpm rating defines a lower-speed operating point. For cabinet ventilation planning, start with the supplied equipment fit. Verify bearing and signal options in the exact datasheet. |
12 | 80x80x25mm | 56.1 | 27.4 | 1.01 | 2600 | 28 | |
![]() GF80251B6-0000-AD9 | SUNON 12V 1.44W 80x80x25mm 62.9m3/h DC Axial Fan for Data Center Cooling SUNON GF80251B6-0000-AD9 combines a 80 × 80 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. Its 2900 rpm rating defines a lower-speed operating point. Use the documented suffix definition when planning cabinet ventilation planning. Verify bearing and signal options in the exact datasheet. |
12 | 80x80x25mm | 62.9 | 37.4 | 1.44 | 2900 | 30 |
我们是一家专注于 SUNON 产品的工业风机与鼓风机供应商,超过 20 年来一直帮助客户针对每一个应用场景正确选型、采购和维护。
应用领域覆盖HVAC 暖通空调与通风、制冷与冷链设备、数据中心散热、工业过程冷却、电子与通信机柜热管理、新能源与电力设备。常用型号我们备有现货,每一条选型建议都附带规格书、尺寸图和性能曲线,方便您在下单前完成选型验证。
除新品供应外,我们还积累了大量替换改造项目经验:当原装 SUNON 型号停产或交期过长时,我们会逐一核对安装尺寸、电气参数和性能曲线,提出无需改动机械结构与接线的兼容替代方案。
我们的服务覆盖设备整个生命周期:售前选型支持、供工程审核的完整规格书与尺寸图、从一个样品到批量供货的弹性数量,以及 SUNON 设备在用期间随时可响应的售后协助。
在对比SUNON的型号之前,先列明真实的运行需求:所需风量、系统静压、可用安装空间和现场供电条件。忽略这四项因素中任何一项的选型,通常最终都会以退货或现场改造收场。
电压和控制方式决定入围范围。标准选项包括 12/24/48 V DC 和 115/230 V AC;对于工作点会变化的场合,支持 PWM 或 0-10 V 输入的 EC 风机可实现精准调速,测速信号则能提供许多安全系统所需的反馈。
环境条件比任何目录筛选器都更快地淘汰不合适的型号。检查环境温度范围、防尘防潮所需的 IP 防护等级以及预期使用寿命——在立式安装或高温位置,滚珠轴承机型保持噪音和风量指标稳定的时间远长于含油轴承设计。如果设备要销往受监管市场,应在此阶段确认 UL、CE 和 RoHS 认证,并尽早设定以 dBA 为单位的噪音目标,避免声学问题在安装后才暴露。
收尾阶段要为订单排除风险:核实库存水平,确认生产交期,并索取候选型号的规格书和尺寸图,确保安装孔位和接口在采购前核对无误。把您的工作点提供给我们,我们将验证匹配性 该分类现有 1,066 件产品可随时对比。
从我们的项目记录看,凡是设备需要持续散热、空气需要持续流动的场合都会用到SUNON:数据中心与机房、商用制冷、空调通风系统、通信与电池柜、工业机械设备,以及新能源领域的电力电子设备。这些项目的共同点很朴素——风机成本占比很小,却直接决定设备能否正常运行,值得与被保护设备同等的工程重视。
在最近一个改造项目中,客户的散热机组必须在更换磨损风机的同时保持运行。我们找到了安装尺寸完全相同、风量-压力曲线相当的在产替换型号,并确认了测速输出兼容性,整个安装在一个维护窗口内完成。
第二类高频场景来自制冷维修:冷凝器或蒸发器风机损坏,而原装型号交期漫长。不必等待——我们核对轴承类型、IP 防护等级、叶轮直径和转速,立即提供能恢复制冷量的等效型号。这正是我们的现货库存保护冷链运行的常见方式之一。
无论新造设备还是 SUNON 设备的替换项目,在我们这里都遵循同一路径:您提供所需的风量、压力和尺寸,我们回复入围清单、性能曲线和确定的交货日期。
每台机组均享受制造商针对材料和工艺缺陷的质保,索赔全程由我们协助处理,您只需对接一家供应商,无需跨国追查工厂。如在使用中出现故障,请提供序列号、运行工况和照片,我们将按报价约定的方式安排更换或退款。
下单前可按需提供规格书、性能曲线、尺寸图和认证文件(视适用情况提供 UL、CE、RoHS)——我们始终认为,采购订单应建立在经过验证的选型之上,而不是取代选型。对于项目投标,我们还可以提供产品对比表,把候选型号按您关注的参数逐项并列呈现。
常规系列和主流电压版本通常备有现货,可在几个工作日内发货;特殊或定制版本按订单生产,一般需要额外的生产时间。您只需提供确切型号或所需参数,我们将在一次回复中确认库存、单价和最早发货日期,该分类目前在线展示 1,066 件产品。
袋装
袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。