制造商料号 Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
MF40200V1-1000U-A99 | SUNON 5V 0.79W 40x40x20mm 8.9m3/h DC Axial Fan for Telecommunications

SUNON MF40200V1-1000U-A99 combines a 40 × 40 × 20 mm DC axial fan platform with a 5 VDC rating for telecom cabinets and network equipment. Its 8.9 m³/h airflow rating suits the stated equipment-cooling role. Treat the motor input as a primary input to replacement evaluation. Check the full suffix before confirming connector details.

5 40*40*20 8.9 - 0.79 7000 25.5
MF60252V1-1000U-A99 | SUNON 24V 1.25W 60x60x25mm 23.5m3/h DC Axial Fan for Telecommunications

The MF60252V1-1000U-A99 is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for telecom cabinets and network equipment. A listed noise value of 27 dB is the model's key differentiator. For replacement evaluation, start with the supplied catalog specification. Check the full suffix before confirming connector details.

24 60*60*25 23.5 - 1.25 4500 27
MF60152V2-1000U-A99 | SUNON 24V 1.06W 60x60x15mm 22.8m3/h DC Axial Fan for Telecommunications

A 60 × 60 × 15 mm frame and 24 VDC rating define MF60152V2-1000U-A99, a DC axial fan for telecom cabinets and network equipment. Its 22.8 m³/h airflow rating suits the stated equipment-cooling role. Use the documented thermal-duty record when planning replacement evaluation. Check the full suffix before confirming connector details.

24 60*60*15 22.8 - 1.06 3900 29.2
MF30060V1-1000U-A99 | SUNON 5V 0.72W 30x30x6mm 4.9m3/h DC Axial Fan for Telecommunications

SUNON MF30060V1-1000U-A99 combines a 30 × 30 × 6 mm DC axial fan platform with a 5 VDC rating for telecom cabinets and network equipment. Its 4.9 m³/h airflow rating suits the stated equipment-cooling role. Review its performance curve during replacement evaluation. Check the full suffix before confirming connector details.

5 30*30*6 4.9 - 0.72 9100 23.6
MF50151V2-1000U-A99 | SUNON 12V 0.61W 50x50x15mm 22.1m3/h DC Axial Fan for Telecommunications

Designed for telecom cabinets and network equipment, SUNON MF50151V2-1000U-A99 is a 12 VDC DC blower in a 50 × 50 × 15 mm frame. A listed input of 0.61 W is the model's notable electrical characteristic. Treat the mounting size as a primary input to replacement evaluation. Check the full suffix before confirming connector details.

12 50*50*15 22.1 - 0.61 5000 29
MF30100V1-1000U-A99 | SUNON 5V 0.69W 30x30x10mm 5.5m3/h DC Axial Fan for Telecommunications

MF30100V1-1000U-A99 serves telecom cabinets and network equipment as a 30 × 30 × 10 mm DC axial fan rated at 5 VDC. Its 5.5 m³/h airflow rating suits the stated equipment-cooling role. During replacement evaluation, compare the model's static-pressure entry. Check the full suffix before confirming connector details.

5 30*30*10 5.5 - 0.69 11000 23
MF35100V1-1000U-A99 | SUNON 5V 0.78W 35x35x10mm 7.2m3/h DC Axial Fan for Telecommunications

The MF35100V1-1000U-A99 is SUNON's 5 VDC, 35 × 35 × 10 mm DC axial fan option for telecom cabinets and network equipment. Its 7.2 m³/h airflow rating suits the stated equipment-cooling role. The recorded volume-flow figure should guide replacement evaluation. Check the full suffix before confirming connector details.

5 35*35*10 7.2 - 0.78 10000 28
MF60151V2-1000U-A99 | SUNON 12V 0.88W 60x60x15mm 22.8m3/h DC Axial Fan for Telecommunications

SUNON MF60151V2-1000U-A99 is a 12 VDC DC blower in a 60 × 60 × 15 mm format for telecom cabinets and network equipment. A listed input of 0.88 W is the model's notable electrical characteristic. For replacement evaluation, start with the supplied sound level. Check the full suffix before confirming connector details.

12 60*60*15 22.8 - 0.88 3900 29.2
MF50152V2-1000U-A99 | SUNON 24V 0.72W 50x50x15mm 13m3/h DC Axial Fan for Telecommunications

SUNON MF50152V2-1000U-A99 combines a 50 × 50 × 15 mm DC axial fan platform with a 24 VDC rating for telecom cabinets and network equipment. Its 13 m³/h airflow rating suits the stated equipment-cooling role. Use the documented rotational rating when planning replacement evaluation. Check the full suffix before confirming connector details.

24 50*50*15 13 - 0.72 5000 29
MF40101V1-1000U-A99 | SUNON 12V 0.72W 40x40x10mm 8m3/h DC Axial Fan for Telecommunications

Used in telecom cabinets and network equipment, SUNON MF40101V1-1000U-A99 is a 12 VDC DC axial fan in a 40 × 40 × 10 mm frame. Its 8 m³/h airflow rating suits the stated equipment-cooling role. Review its power demand during replacement evaluation. Check the full suffix before confirming connector details.

12 40*40*10 8 - 0.72 7000 27.3
MF40201VX-1000U-A99 | SUNON 12V 1.06W 40x40x20mm 10.8m3/h DC Axial Fan for Telecommunications

Within telecom cabinets and network equipment, SUNON MF40201VX-1000U-A99 serves as a 40 × 40 × 20 mm DC axial fan operating at 12 VDC. Its 10.8 m³/h airflow rating suits the stated equipment-cooling role. Treat the frame geometry as a primary input to replacement evaluation. Check the full suffix before confirming connector details.

12 40*40*20 10.8 - 1.06 8000 27.5
MF20100V1-1000U-A99 | SUNON 5V 0.88W 20x20x10mm 1.9m3/h DC Axial Fan for Telecommunications

MF20100V1-1000U-A99 addresses telecom cabinets and network equipment through a 5 VDC DC axial fan platform measuring 20 × 20 × 10 mm. Its 1.9 m³/h airflow rating suits the stated equipment-cooling role. Base replacement evaluation on the stated cooling output. Check the full suffix before confirming connector details.

5 20*20*10 1.9 - 0.88 16500 25
MF40101VX-1000U-A99 | SUNON 12V 1.17W 40x40x10mm 9.9m3/h DC Axial Fan for Telecommunications

The MF40101VX-1000U-A99 is SUNON's 12 VDC, 40 × 40 × 10 mm DC axial fan option for telecom cabinets and network equipment. Its 9.9 m³/h airflow rating suits the stated equipment-cooling role. During replacement evaluation, compare the model's operating point. Check the full suffix before confirming connector details.

12 40*40*10 9.9 - 1.17 8000 31.4
MF80251V1-1000U-G99 | SUNON 12V 1.44W 80x80x25mm 69.7m3/h DC Axial Fan for Telecommunications

For compact cooling within telecom cabinets and network equipment, the MF80251V1-1000U-G99 provides a 12 VDC DC axial fan configuration measuring 80 × 80 × 25 mm. Its 3200 rpm rating defines a lower-speed operating point. The recorded pressure capability should guide replacement evaluation. Check the full suffix before confirming connector details.

12 80*80*25 69.7 - 1.44 3200 33
MF20080V1-1000U-A99 | SUNON 5V 0.72W 20x20x8mm 1.6m3/h DC Axial Fan for Telecommunications

Within telecom cabinets and network equipment, SUNON MF20080V1-1000U-A99 serves as a 20 × 20 × 8 mm DC axial fan operating at 5 VDC. Its 1.6 m³/h airflow rating suits the stated equipment-cooling role. Review its electrical load during replacement evaluation. Check the full suffix before confirming connector details.

5 20*20*8 1.6 - 0.72 15000 23
MF50152V1-1000U-G99 | SUNON 24V 1.08W 50x50x15mm 17m3/h DC Axial Fan for Telecommunications

For thermal management in telecom cabinets and network equipment, the MF50152V1-1000U-G99 provides a 24 VDC DC axial fan configuration measuring 50 × 50 × 15 mm. Its 17 m³/h airflow rating suits the stated equipment-cooling role. During enclosure sizing, compare the model's application data. Verify bearing and signal options in the exact datasheet.

24 50*50*15 17 - 1.08 6100 33
MF60152VX-1000U-A99 | SUNON 24V 2.04W 60x60x15mm 30.4m3/h DC Axial Fan for Telecommunications

Positioned for telecom cabinets and network equipment, SUNON MF60152VX-1000U-A99 is a 24 VDC DC axial fan in a 60 × 60 × 15 mm frame. Its 30.4 m³/h airflow rating suits the stated equipment-cooling role. For enclosure sizing, start with the supplied model record. Verify bearing and signal options in the exact datasheet.

24 60*60*15 30.4 - 2.04 5400 36.2
MF50151V1-1000U-G99 | SUNON 12V 0.92W 50x50x15mm 17m3/h DC Axial Fan for Telecommunications

SUNON MF50151V1-1000U-G99 combines a 50 × 50 × 15 mm DC blower platform with a 12 VDC rating for telecom cabinets and network equipment. Its 17 m³/h airflow rating suits the stated equipment-cooling role. During enclosure sizing, compare the model's installation footprint. Verify bearing and signal options in the exact datasheet.

12 50*50*15 17 - 0.92 6100 33
MF40201VX-1000U-G99 | SUNON 12V 0.96W 40x40x20mm 18.3m3/h DC Axial Fan for Telecommunications

Built around telecom cabinets and network equipment, SUNON MF40201VX-1000U-G99 is a 12 VDC DC axial fan in a 40 × 40 × 20 mm frame. 8000 rpm is the model's most distinctive operating parameter. The recorded selection parameters should guide enclosure sizing. Verify bearing and signal options in the exact datasheet.

12 40x40x20 18.3 72.2 0.96 8000 27.5
MF25100V1-1000U-A99 | SUNON 5V 0.58W 25x25x10mm 3.5m3/h DC Axial Fan for Telecommunications

Within telecom cabinets and network equipment, SUNON MF25100V1-1000U-A99 serves as a 25 × 25 × 10 mm DC axial fan operating at 5 VDC. Its 3.5 m³/h airflow rating suits the stated equipment-cooling role. For enclosure sizing, start with the supplied rated dataset. Verify bearing and signal options in the exact datasheet.

5 25*25*10 3.5 - 0.58 13000 23
显示
261-280
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-301
共 301 个
1 2 ... 7 8 9 10 11 12 13 14 15 16
跳转 页

关于电信

如何选择合适的电信

选择合适的电信,应从工作点出发而不是从型号名称出发。先确定您实际需要的风量(CFM 或 m³/h)以及风机需要克服的静压,再寻找性能曲线能以一定裕量穿过该工作点的机型,而不是刚好压在曲线边缘的产品。

电气细节要尽早确认。DC 风机通常采用 12/24/48 V 供电,易于与控制板集成;AC 风机适合 115/230 V 定速安装场合。如果风量需要随负载变化,请选择支持 PWM 或模拟量控制的 EC 技术;在需要状态监控的场合,测速输出可以让控制器及时发现风机故障。

下一步是环境与认证。根据粉尘和潮湿暴露程度匹配 IP 防护等级,凡在高温、立式或全天候连续运行的场合,优先选择滚珠轴承,并对照目标市场确认 UL、CE、RoHS 等认证。尽早以 dBA 设定声学限值,可以避免第一台样机噪声过大时的后期返工。

最后,请从整体供货风险而非单纯价格来比较候选型号:确认所需数量的现货情况,核实后续批次的交期,并在确认前索取规格书和尺寸图。报价前,我们的团队会为您交叉核对曲线、尺寸和电气参数 该分类目前有 301 件产品可供对比。

电信的典型应用场景与案例

电信几乎出现在所有需要可靠排热或换气的行业。典型环境包括机房与数据中心、制冷冷凝器与冷库蒸发器、暖通空调组合式空调机组、通信机柜、医疗与实验室设备、焊接与数控机床机壳,以及新能源电力柜。在这些场景中,风机都是关键部件:一旦故障就意味着停产、货物受损或代价高昂的紧急停机。

一个反复出现的场景来自控制柜改造:原装风机已停产,安装孔位不能改动,停机时间以小时计。我们按机壳尺寸、风量和噪音将旧型号与在产系列逐一比对,提出最接近的直接替换方案,并随货附上规格书,让电工无需重新设计即可接线。

对冷库运营方来说,痛点很直接:蒸发器或冷凝器风机故障必须立即更换,而不是等六周的进口周期。将叶轮直径、转速和防护等级与现货等效型号逐一比对,我们能在几天内恢复制冷能力——备件替换供应也因此成为我们在该分类下的核心业务。

无论您是在制造新设备还是维护既有设备,流程都一样:把工作点和约束条件发给我们,我们回报经过验证的选型结果,并附规格书、性能曲线和明确的交期。

电信采购常见问题解答

电信是否有现货?多久可以发货?

常规系列和主流电压版本通常备有现货,可在几个工作日内发货;特殊或定制版本按订单生产,一般需要额外的生产时间。您只需提供确切型号或所需参数,我们将在一次回复中确认库存、单价和最早发货日期,该分类目前在线展示 301 件产品。

能否替换我在用的其他供应商的电信或已停产的型号?

可以。备件替换供应是我们的核心服务之一:我们会逐一核对您在用机组的安装尺寸、电压、转速和性能曲线,提出最接近的在产系列等效型号。如机壳或接口略有差异,我们会在下单前明确告知差异,确保替换安装不出现意外。

批量采购前可以单件下单或申请样品吗?

欢迎单件订购和样品申请——许多客户都会先在系统中验证一台样机,再决定批量采购。标准现货型号不设最低起订量,且多数复购订单可在批量货款中抵扣样品费。请告诉我们计划使用的数量,我们将同时给出两种方案的报价。

袋装

袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。