获取报价
首页 > 产品 > 按类型 > 鼓风机 > AFB1224HHE | Delta Electronics 24VDC 6.48W Axial Fan for Server and Power Supply Cooling

AFB1224HHE Delta 鼓风机

品牌:
Delta
型号:
AFB1224HHE | Delta Electronics 24VDC 6.48W Axial Fan for Server and Power Supply Cooling
类型:
鼓风机
应用行业:
数据中心冷却
产品描述:

A listed 3500 rpm speed and 6.48 W input identify AFB1224HHE for server and power-supply cooling. This 24VDC axial fan has a 120 x 120 x 38 mm frame, providing a specific fit for 38 mm-deep installations.

规格书:
AFB1224HHE | Delta Electronics 24VDC 6.48W Axial Fan for Server and Power Supply Cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)24
Size(mm)120*120*38
Max.Air Flow(m³/h)222
Max.Pressure(Pa)9
Input Power(W)6.48
Speed(rpm)3500
Noise(db)47

产品特点

DC Equipment Cooling

For industrial control equipment, the AFB1224HHE from Delta is a brushless DC axial fan that supports active thermal management. A planned inlet-to-outlet route helps the installation carry component heat away.

Its listed 120 x 120 x 38 mm format defines the space needed for installation, helping designers reserve room for adjacent components and cable routing. The series uses ball-bearing motor support for rotational durability, giving OEMs a service-life-oriented construction for equipment cooling. A controlled exhaust route limits recirculation, allowing the delivered air to carry heat away rather than return to the inlet.

It suits engineering buyers who need a defined cooling component. Verify the exact wiring and environmental limits before approving long-term installation.

应用行业

常见问题

What maximum airflow is listed for AFB1224HHE?

The workbook lists a maximum airflow of 222 m3/h. This is not the airflow at every system resistance; use the applicable pressure-flow curve to identify the installed operating point.

What equipment is AFB1224HHE intended to cool?

AFB1224HHE is listed for Server and Power Supply cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.

How should the energy efficiency of AFB1224HHE be assessed?

The listed input-power figure is 6.48 W, but efficiency must be evaluated at the required airflow and pressure. Check the applicable fan curve and test conditions before comparison.

Is AFB1224HHE easy to install and maintain?

Serviceability depends on access, connector choice and mounting. Plan isolation and cleaning access, inspect the airflow path, and use the manufacturer's replacement guidance rather than attempting an unsupported repair.

Can AFB1224HHE directly replace another fan?

A matching outline alone does not prove compatibility. Check 24VDC, mounting dimensions, connector, pinout, airflow direction, control signals and the required pressure-flow point.

在线留言