首页 > 产品 > 按类型 > 鼓风机 > FFB03812VHN | Delta Electronics 12VDC 10.2W Axial Fan for Server and Telecommunications Cooling

FFB03812VHN Delta 鼓风机

品牌:
Delta
型号:
FFB03812VHN | Delta Electronics 12VDC 10.2W Axial Fan for Server and Telecommunications Cooling
类型:
鼓风机
应用行业:
数据中心冷却
产品描述:

FFB03812VHN puts a 23000 rpm axial fan assembly into a 38 x 38 x 28 mm space. Listed for server and telecom cooling on 12VDC, it has an 846.9 Pa maximum static-pressure specification and 10.2 W input.

规格书:
FFB03812VHN | Delta Electronics 12VDC 10.2W Axial Fan for Server and Telecommunications Cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)12
Size(mm)38x38x28
Max.Air Flow(m³/h)38.6
Max.Pressure(Pa)846.9
Input Power(W)10.2
Speed(rpm)23000
Noise(db)62.5

产品特点

DC Equipment Cooling

The FFB03812VHN addresses ventilation needs in telecommunications equipment. Delta's brushless DC axial fan format allows cooling airflow to be integrated alongside the equipment's heat-producing assemblies.

The listed 10.2 W input is relevant to supply sizing and the system energy budget; actual consumption depends on the operating duty. Its high-performance fan family emphasizes air delivery and pressure capability, helping address the resistance of densely populated equipment. Selecting the operating point against real pressure loss helps avoid oversizing and keeps thermal design focused on useful air delivery.

Equipment manufacturers and maintenance teams should match the complete part number and installation limits for reliable operation across the service cycle.

应用行业

常见问题

Can FFB03812VHN run continuously in 24/7 equipment?

The supplied filter data does not establish an unconditional 24/7 rating. Confirm bearing life, temperature range, duty cycle and derating in the exact datasheet, then validate system-level redundancy.

How should the pressure capability of FFB03812VHN be checked?

The workbook lists 846.9 Pa maximum pressure. Maximum pressure and maximum airflow occur at different points, so select FFB03812VHN from its curve at the required system resistance.

What should be checked if FFB03812VHN fails to start?

Isolate power first. Verify the approved supply, connector, polarity or phase, control-enable input and any obstruction; follow the exact specification and do not bypass protection circuits.

What equipment is FFB03812VHN intended to cool?

FFB03812VHN is listed for Server and Telecommunications cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.

What power figure is listed for FFB03812VHN?

10.2 W is shown in the filter data. Check whether the corresponding datasheet defines it as rated, free-air or maximum-load input before sizing the power source.