获取报价
首页 > 产品 > 按类型 > 鼓风机 > FFB0812SH | Delta Electronics 12VDC 6W Axial Fan for Server and Telecommunications Cooling

FFB0812SH Delta 鼓风机

品牌:
Delta
型号:
FFB0812SH | Delta Electronics 12VDC 6W Axial Fan for Server and Telecommunications Cooling
类型:
鼓风机
应用行业:
数据中心冷却
产品描述:

FFB0812SH combines a 4500 rpm axial fan rotor with 12VDC operation for server and telecom enclosures. Its 80 x 80 x 25.4 mm dimensions are paired with a listed 97.58 Pa maximum static pressure and 6 W input.

规格书:
FFB0812SH | Delta Electronics 12VDC 6W Axial Fan for Server and Telecommunications Cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)12
Size(mm)80x80x25.4
Max.Air Flow(m³/h)113.88
Max.Pressure(Pa)97.58
Input Power(W)6
Speed(rpm)4500
Noise(db)48.6

产品特点

DC Equipment Cooling

In uninterruptible power systems, Delta FFB0812SH supplies the forced-air element of the cooling system. As a brushless DC axial fan, it is intended for integration into a defined mechanical and electrical assembly.

The listed 6 W input is relevant to supply sizing and the system energy budget; actual consumption depends on the operating duty. Its high-performance fan family emphasizes air delivery and pressure capability, helping address the resistance of densely populated equipment. Good inlet spacing helps reduce turbulence, which matters when balancing usable cooling capacity against installed sound levels.

For OEM design-in and replacement sourcing, confirm the full suffix, connector and mounting pattern to support dependable service in the intended assembly.

应用行业

常见问题

Is stock and lead time stable for FFB0812SH?

In Stock is shown in the workbook, but this is not a delivery guarantee. Confirm the complete part number, quantity, current inventory and committed lead time when ordering.

Does FFB0812SH support speed control?

The filter data does not confirm a control interface. Check the exact-model datasheet and wiring for PWM, analog control, FG/RD feedback or fixed-speed operation before connection.

What equipment is FFB0812SH intended to cool?

FFB0812SH is listed for Server and Telecommunications cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.

Can FFB0812SH run continuously in 24/7 equipment?

The supplied filter data does not establish an unconditional 24/7 rating. Confirm bearing life, temperature range, duty cycle and derating in the exact datasheet, then validate system-level redundancy.

What maximum airflow is listed for FFB0812SH?

The workbook lists a maximum airflow of 113.88 m3/h. This is not the airflow at every system resistance; use the applicable pressure-flow curve to identify the installed operating point.

What installation space is required for FFB0812SH?

The workbook lists 80x80x25.4 mm. Confirm overall depth, hole pattern, connector clearance and guard or inlet-ring dimensions in the exact mechanical drawing.