首页 > 产品 > 按类型 > 轴流风机 > GTW091PUU23E | Delta Electronics 3~380-480VAC 3100W EC Axial Fan for Server and Precision Cooling

GTW091PUU23E Delta 轴流风机

品牌:
Delta
型号:
GTW091PUU23E | Delta Electronics 3~380-480VAC 3100W EC Axial Fan for Server and Precision Cooling
类型:
轴流风机
应用行业:
数据中心冷却
产品描述:

The GTW091PUU23E is an EC axial fan for server and precision cooling, listed for three-phase 380-480VAC. Its PDF records 36185.9 m3/h at free air and 1100 rpm without a fan guard, identifying the test condition.

规格书:
GTW091PUU23E | Delta Electronics 3~380-480VAC 3100W EC Axial Fan for Server and Precision Cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)3~380-480
Size(mm)910
Max.Air Flow(m³/h)36186
Max.Pressure(Pa)219
Input Power(W)3100
Speed(rpm)1100
Noise(db)86

产品特点

EC Axial Cooling

Delta GTW091PUU23E serves server and storage equipment as an EC axial fan. Equipment builders can use its mechanical format to establish forced ventilation near heat-producing parts.

The listed 3100 W power rating is relevant to supply sizing and the system energy budget; actual consumption depends on the operating duty. Ball-bearing motor support provides a durable rotating assembly for repeated operating duty. Good inlet spacing helps reduce turbulence, which matters when balancing usable cooling capacity against installed sound levels.

Equipment manufacturers and maintenance teams should match the complete part number and installation limits for reliable operation across the service cycle.

应用行业

常见问题

How should the energy efficiency of GTW091PUU23E be assessed?

The listed input-power figure is 3100 W, but efficiency must be evaluated at the required airflow and pressure. Check the applicable fan curve and test conditions before comparison.

Can GTW091PUU23E run continuously in 24/7 equipment?

The supplied filter data does not establish an unconditional 24/7 rating. Confirm bearing life, temperature range, duty cycle and derating in the exact datasheet, then validate system-level redundancy.

How should noise from GTW091PUU23E be evaluated?

The listed noise value is 86 dB, but compare values only under matching test conditions. Installed noise also depends on speed, restriction, resonance and enclosure geometry.

Does GTW091PUU23E support speed control?

The filter data does not confirm a control interface. Check the exact-model datasheet and wiring for PWM, analog control, FG/RD feedback or fixed-speed operation before connection.

What installation space is required for GTW091PUU23E?

The workbook lists 910 mm. Confirm overall depth, hole pattern, connector clearance and guard or inlet-ring dimensions in the exact mechanical drawing.

What equipment is GTW091PUU23E intended to cool?

GTW091PUU23E is listed for Server and Precision cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.