获取报价
首页 > 产品 > 按类型 > 鼓风机 > RG125-19/96 | ebm-papst 230V 20W Centrifugal Blower for Boilers

RG125-19/96 ebm-papst 鼓风机

品牌:
ebmpapst
型号:
RG125-19/96 | ebm-papst 230V 20W Centrifugal Blower for Boilers
类型:
鼓风机
应用行业:
暖通空调与通风
产品描述:

Intended for Boilers, the ebm-papst RG125-19/96 is a 230 V AC forward-curved centrifugal fan, with a focus on a documented 20 W input rating. It gives engineers a clear comparison point.

规格书:
RG125-19/96 | ebm-papst 230V 20W Centrifugal Blower for Boilers 规格书 (Pdf)

产品特点

Rated Voltage(V)230
Size(mm)180*180*33.5
Max.Air Flow(m³/h)86
Input Power(W)20
Speed(rpm)2 550

产品特点

Reliable AC Cooling

The ebm-papst RG125-19/96 is an AC centrifugal blower for HVAC and Ventilation, combining application-focused airflow with practical integration criteria. It serves equipment manufacturers and maintenance teams that require traceable model selection.

Documented selection points include 230 V supply, 20 W input, 180*180*33.5 mm size, up to 86 m3/h airflow. These values support electrical, envelope and duty-point comparison.

For procurement, verify voltage, duty point, dimensions, connector and mounting. Correct sizing and clear airflow paths support stable operation, controlled noise and long service life. Confirm speed control, IP protection and approvals in the exact-model datasheet. Service access and clean inlets help protect cooling performance over time.

应用行业

产品资讯

Typical Applications — RG125-19/96 AC Radial

Condenser Cooling: The RG125-19/96 axial fan excels at condenser heat rejection in refrigeration and HVAC.

AHU Air Handling: Engineered for integration into Air Handling Units.

Industrial Process Ventilation: Machinery cooling, enclosure ventilation and process air movement. Hengrui provides custom engineering support.

常见问题

What installation checks apply to the RG125-19/96?

Verify mounting orientation, inlet and outlet clearance, fastener security, electrical connections and the exact dimensional drawing before startup.

How can noise be managed when using the RG125-19/96?

Noise data is not listed in the supplied table. Use unobstructed airflow, secure mounting and suitable isolation where required.

What should be inspected if airflow drops on the RG125-19/96?

Check for blocked airflow paths, incorrect supply, loose wiring, abnormal rotation or system resistance before consulting the exact service documentation.

Is the RG125-19/96 suitable for high-reliability cooling?

It can be evaluated for demanding service using the documented ratings, installation limits and preventive-maintenance plan for the application.