获取报价
首页 > 产品 > 按类型 > 轴流风机 > 109-602 | Sanyo Denki 200VAC 37.5W San Ace AC Axial Fan for industrial fan cooling systems

109-602 三洋 轴流风机

品牌:
三洋
型号:
109-602 | Sanyo Denki 200VAC 37.5W San Ace AC Axial Fan for industrial fan cooling systems
类型:
轴流风机
应用行业:
工业冷却
产品描述:

The 160 × 160 × 51 mm Sanyo Denki 109-602 brings 200 VAC AC axial fan cooling to industrial equipment cooling. Series options require suffix verification. Base spares assessment on the stated cooling specification. Verify the exact bearing and signal options in the datasheet. Focus: enclosure space planning speed benchmark.

规格书:
109-602 | Sanyo Denki 200VAC 37.5W San Ace AC Axial Fan for industrial fan cooling systems 规格书 (Pdf)

产品特点

Rated Voltage(V)200
Size(mm)160*160*51
Max.Air Flow(m³/h)432
Max.Pressure(Pa)156.8
Input Power(W)37.5
Speed(rpm)2850
Noise(db)56

产品特点

Stable San Ace Fan

The San Ace 109-602 serves industrial machinery and electrical enclosures as a AC axial fan. Its airflow supports heat transfer from internal devices toward cabinet or chassis exhaust openings.

With up to 432 m3/h airflow and 156.8 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. The motor, frame and impeller form a rigid airflow assembly that helps control vibration and preserve operating stability. Efficient air delivery reduces unnecessary cooling overhead. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.

Test component temperatures at peak load. This gives purchasing a controlled replacement reference.

应用行业

常见问题

Does 109-602 have a pressure rating?

The worksheet lists 156.8 Pa. Use the official curve to match it to system resistance.

What equipment is 109-602 suited to?

It is listed for industrial equipment cooling. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.

What IP protection is documented for 109-602?

No exact IP rating is supplied for this model row. Check the current model datasheet before use in water, dust, or oil exposure.

What maintenance does 109-602 require?

Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.

Can 109-602 reduce total operating cost?

Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.

What input power is listed for 109-602?

The worksheet lists 37.5 W. Check supply capacity and operating conditions before commissioning.