获取报价
首页 > 产品 > 按类型 > 轴流风机 > 109E4724H401 | Sanyo Denki 24VDC 24W DC Axial Fan for UPS, server and telecom equipment cooling

109E4724H401 三洋 轴流风机

品牌:
三洋
型号:
109E4724H401 | Sanyo Denki 24VDC 24W DC Axial Fan for UPS, server and telecom equipment cooling
类型:
轴流风机
应用行业:
数据中心冷却
产品描述:

The 109E4724H401 is a Sanyo Denki 24 VDC, φ172 × 25 mm DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. During power-budget planning, compare the model's suffix definition. Review connector, alarm, and sensor options separately. Focus: acoustic limit assessment power demand.

规格书:
109E4724H401 | Sanyo Denki 24VDC 24W DC Axial Fan for UPS, server and telecom equipment cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)24
Size(mm)φ172*25
Max.Air Flow(m³/h)384
Max.Pressure(Pa)135
Input Power(W)24
Speed(rpm)3400
Noise(db)57

产品特点

High Airflow Design

For servers, storage systems and ICT equipment, the SANYO DENKI 109E4724H401 provides DC axial fan cooling in an integration-ready format. It establishes an active air path through restricted equipment spaces.

With up to 384 m3/h airflow and 135 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.

Check startup demand against the power supply. This keeps sourcing decisions tied to validated system needs. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

应用行业

常见问题

How should 109E4724H401 be matched to an enclosure?

Check its φ172 × 25 mm size, 384 m³/h airflow, 135 Pa pressure, mounting points, airflow direction, and system resistance.

What equipment is 109E4724H401 suited to?

It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.

What IP protection is documented for 109E4724H401?

No exact IP rating is supplied for this model row. Check the current model datasheet before use in water, dust, or oil exposure.

What maintenance does 109E4724H401 require?

Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.

Can 109E4724H401 reduce total operating cost?

Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.

How noisy is 109E4724H401?

The worksheet lists 57 dB. Enclosure acoustics, system resistance, and distance can change the installed result.