For servers, UPS systems, and telecom equipment, 109E5724H5D01 combines 24 VDC operation with a 172 × 150 × 51 mm DC axial fan design. Series focus: high airflow and pressure. Its listed airflow of 379.8 m³/h is the standout performance value. Check airflow path balancing installation footprint. Focus: airflow path balancing installation footprint.

规格书:
109E5724H5D01 | Sanyo Denki 24VDC 13.92W DC Axial Fan for UPS, server and telecom equipment cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)24
Size(mm)172*150*51
Max.Air Flow(m³/h)379.8
Max.Pressure(Pa)137.2
Input Power(W)13.92
Speed(rpm)3050
Noise(db)52

产品特点

Low Vibration Fan

For servers, storage systems and ICT equipment, the SANYO DENKI 109E5724H5D01 provides DC axial fan cooling in an integration-ready format. It establishes an active air path through restricted equipment spaces.

The rated peak airflow of 379.8 m3/h combines with 137.2 Pa pressure capability to support useful flow after installation losses are considered. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.

Include filter loading in the airflow margin. This gives purchasing a controlled replacement reference. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

应用行业

常见问题

What bearing type does 109E5724H5D01 use?

The exact bearing is not stated in the supplied row. Confirm it from the complete model suffix and current Sanyo Denki datasheet.

How should 109E5724H5D01 be matched to an enclosure?

Check its 172 × 150 × 51 mm size, 379.8 m³/h airflow, 137.2 Pa pressure, mounting points, airflow direction, and system resistance.

What equipment is 109E5724H5D01 suited to?

It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.

Which application details matter most for 109E5724H5D01?

Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.

What airflow is listed for 109E5724H5D01?

The worksheet lists 379.8 m³/h. Compare the operating point with system resistance and the official performance curve.