首页 > 产品 > 按类型 > 轴流风机 > 109E5724K501 | Sanyo Denki 24VDC 31.2W DC Axial Fan for UPS, server and telecom equipment cooling

109E5724K501 三洋 轴流风机

品牌:
三洋
型号:
109E5724K501 | Sanyo Denki 24VDC 31.2W DC Axial Fan for UPS, server and telecom equipment cooling
类型:
轴流风机
应用行业:
数据中心冷却
产品描述:

The 172 × 150 × 51 mm Sanyo Denki 109E5724K501 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. The recorded motor input should guide airflow-path design. Check the full suffix before confirming connector details.

规格书:
109E5724K501 | Sanyo Denki 24VDC 31.2W DC Axial Fan for UPS, server and telecom equipment cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)24
Size(mm)172*150*51
Max.Air Flow(m³/h)510
Max.Pressure(Pa)243
Input Power(W)31.2
Speed(rpm)4100
Noise(db)60

产品特点

Reliable Fan Cooling

SANYO DENKI positions 109E5724K501 as a DC axial fan for servers, storage systems and ICT equipment. It helps equipment designers manage local hot spots where natural convection is insufficient.

A listed maximum airflow of 510 m3/h and maximum pressure of 243 Pa give engineers a clear basis for matching the fan to enclosure resistance. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.

Confirm the operating environment for the suffix. The process documents the required installation conditions. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

应用行业

常见问题

What should procurement confirm for 109E5724K501?

Confirm full suffix, voltage, connector, control signal, bearing, IP rating, certifications, stock, and required delivery date.

Which specifications define 109E5724K501?

Use rated voltage, 172 × 150 × 51 mm dimensions, 510 m³/h airflow, 4100 rpm, and 31.2 W input for preliminary comparison.

Is 109E5724K501 suitable for high-reliability cooling?

Evaluate the exact bearing, life, temperature, alarm, and protection data. Correct sizing and clean airflow are also required for reliable operation.

Which application details matter most for 109E5724K501?

Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.

What airflow is listed for 109E5724K501?

The worksheet lists 510 m³/h. Compare the operating point with system resistance and the official performance curve.