首页 > 产品 > 按类型 > 轴流风机 > 109E5748C502 | Sanyo Denki 48VDC 57.6W DC Axial Fan for UPS, server and telecom equipment cooling

109E5748C502 三洋 轴流风机

品牌:
三洋
型号:
109E5748C502 | Sanyo Denki 48VDC 57.6W DC Axial Fan for UPS, server and telecom equipment cooling
类型:
轴流风机
应用行业:
数据中心冷却
产品描述:

109E5748C502 serves servers, UPS systems, and telecom equipment as a 172 × 150 × 51 mm DC axial fan rated at 48 VDC. Series focus: high airflow and pressure. Its listed airflow of 594.6 m³/h is the standout performance value. Check thermal margin assessment acoustic value. Focus: thermal margin assessment acoustic value.

规格书:
109E5748C502 | Sanyo Denki 48VDC 57.6W DC Axial Fan for UPS, server and telecom equipment cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)48
Size(mm)172*150*51
Max.Air Flow(m³/h)594.6
Max.Pressure(Pa)308
Input Power(W)57.6
Speed(rpm)4800
Noise(db)66

产品特点

Pressure Cooling

For servers, storage systems and ICT equipment, the SANYO DENKI 109E5748C502 provides DC axial fan cooling in an integration-ready format. It establishes an active air path through restricted equipment spaces.

A listed maximum airflow of 594.6 m3/h and maximum pressure of 308 Pa give engineers a clear basis for matching the fan to enclosure resistance. For design approval, verify airflow direction, connector details and available control signals. Prototype testing should include the final vents, guards and component loading.

Include filter loading in the airflow margin. This step reduces uncertainty during equipment qualification. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

应用行业

常见问题

What IP protection is documented for 109E5748C502?

No exact IP rating is supplied for this model row. Check the current model datasheet before use in water, dust, or oil exposure.

What maintenance does 109E5748C502 require?

Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.

Can 109E5748C502 reduce total operating cost?

Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.

What input power is listed for 109E5748C502?

The worksheet lists 57.6 W. Check supply capacity and operating conditions before commissioning.

Can 109E5748C502 run continuously in a 24/7 system?

Verify the exact bearing, rated life, temperature range, and duty limits. The supplied family description alone does not confirm continuous operation for every suffix.