获取报价
首页 > 产品 > 按类型 > 轴流风机 > 109P0412G3013 | Sanyo Denki 12VDC 3.72W DC Axial Fan for UPS, server and telecom equipment cooling

109P0412G3013 三洋 轴流风机

品牌:
三洋
型号:
109P0412G3013 | Sanyo Denki 12VDC 3.72W DC Axial Fan for UPS, server and telecom equipment cooling
类型:
轴流风机
应用行业:
数据中心冷却
产品描述:

A 40 × 40 × 28 mm frame and 12 VDC rating define 109P0412G3013, a DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. The 25.2 m³/h airflow figure supports its stated equipment-cooling role. Check selection criteria review performance curve. Focus: selection criteria review performance curve.

规格书:
109P0412G3013 | Sanyo Denki 12VDC 3.72W DC Axial Fan for UPS, server and telecom equipment cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)12
Size(mm)40*40*28
Max.Air Flow(m³/h)25.2
Max.Pressure(Pa)179
Input Power(W)3.72
Speed(rpm)11500
Noise(db)42

产品特点

Reliable Fan Cooling

The San Ace 109P0412G3013 serves servers, storage systems and ICT equipment as a DC axial fan. Its airflow supports heat transfer from internal devices toward cabinet or chassis exhaust openings.

The rated peak airflow of 25.2 m3/h combines with 179 Pa pressure capability to support useful flow after installation losses are considered. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.

Review airflow direction before design release. This keeps sourcing decisions tied to validated system needs. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

应用行业

常见问题

Can 109P0412G3013 replace another fan directly?

Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.

What maintenance does 109P0412G3013 require?

Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.

Why choose 109P0412G3013 instead of a standard fan?

Its 12 VDC rating and documented the 25.2 m³/h airflow figure supports its stated equipment-cooling role. provide model-specific selection data without relying on unlisted claims.

How noisy is 109P0412G3013?

The worksheet lists 42 dB. Enclosure acoustics, system resistance, and distance can change the installed result.

Can 109P0412G3013 run continuously in a 24/7 system?

Verify the exact bearing, rated life, temperature range, and duty limits. The supplied family description alone does not confirm continuous operation for every suffix.

在线留言