获取报价
首页 > 产品 > 按类型 > 轴流风机 > 109P0412H902 | Sanyo Denki 12VDC 0.84W DC Axial Fan for UPS, server and telecom equipment cooling

109P0412H902 三洋 轴流风机

品牌:
三洋
型号:
109P0412H902 | Sanyo Denki 12VDC 0.84W DC Axial Fan for UPS, server and telecom equipment cooling
类型:
轴流风机
应用行业:
数据中心冷却
产品描述:

Sanyo Denki 109P0412H902 combines a 40 × 40 × 10 mm DC axial fan platform with a 12 VDC rating for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. The 9.01 m³/h airflow figure supports its stated equipment-cooling role. Focus: cabinet ventilation planning supply requirement.

规格书:
109P0412H902 | Sanyo Denki 12VDC 0.84W DC Axial Fan for UPS, server and telecom equipment cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)12
Size(mm)40*40*10
Max.Air Flow(m³/h)9.01
Max.Pressure(Pa)41.1
Input Power(W)0.84
Speed(rpm)6200
Noise(db)25

产品特点

Reliable Fan Cooling

109P0412H902 is intended for dependable forced-air cooling in servers, storage systems and ICT equipment. This SANYO DENKI DC axial fan fits equipment designs where thermal stability affects service continuity.

The rated peak airflow of 9.01 m3/h combines with 41.1 Pa pressure capability to support useful flow after installation losses are considered. OEM qualification should check startup demand, installation orientation and the exact electrical interface. Installed sound and airflow depend on the surrounding cabinet structure.

Verify the mating connector and lead reach. The review links cooling performance to the approved BOM. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

应用行业

常见问题

Is 109P0412H902 easy to install and maintain?

Confirm connector and mounting details, keep the airflow path clear, and isolate power before cleaning or service.

Which specifications define 109P0412H902?

Use rated voltage, 40 × 40 × 10 mm dimensions, 9.01 m³/h airflow, 6200 rpm, and 0.84 W input for preliminary comparison.

Is 109P0412H902 suitable for high-reliability cooling?

Evaluate the exact bearing, life, temperature, alarm, and protection data. Correct sizing and clean airflow are also required for reliable operation.

Which application details matter most for 109P0412H902?

Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.

Does 109P0412H902 support PWM speed control?

PWM or sensor functions depend on the exact suffix. Confirm the control lead and interface in the applicable Sanyo Denki datasheet.

在线留言