获取报价
首页 > 产品 > 按类型 > 轴流风机 > 109P0424G3023 | Sanyo Denki 24VDC 4.56W DC Axial Fan for UPS, server and telecom equipment cooling

109P0424G3023 三洋 轴流风机

品牌:
三洋
型号:
109P0424G3023 | Sanyo Denki 24VDC 4.56W DC Axial Fan for UPS, server and telecom equipment cooling
类型:
轴流风机
应用行业:
数据中心冷却
产品描述:

Sanyo Denki 109P0424G3023 combines a 40 × 40 × 28 mm DC axial fan platform with a 24 VDC rating for servers, UPS systems, and telecom equipment. The supplied reference emphasizes high static pressure and high airflow. The 24.8 m³/h airflow figure supports its stated equipment-cooling role. Focus: cooling margin validation system interface.

规格书:
109P0424G3023 | Sanyo Denki 24VDC 4.56W DC Axial Fan for UPS, server and telecom equipment cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)24
Size(mm)40*40*28
Max.Air Flow(m³/h)24.8
Max.Pressure(Pa)179
Input Power(W)4.56
Speed(rpm)11500
Noise(db)42

产品特点

High Airflow Design

The San Ace 109P0424G3023 serves servers, storage systems and ICT equipment as a DC axial fan. Its airflow supports heat transfer from internal devices toward cabinet or chassis exhaust openings.

With up to 24.8 m3/h airflow and 179 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.

Measure installed sound in the final cabinet. It helps maintenance teams plan compatible replacements. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

应用行业

常见问题

Can 109P0424G3023 replace another fan directly?

Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.

What maintenance does 109P0424G3023 require?

Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.

Can 109P0424G3023 reduce total operating cost?

Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.

What supply voltage does 109P0424G3023 require?

The worksheet lists 24 VDC. Check polarity or AC frequency and the wiring diagram before commissioning.

What should be checked if 109P0424G3023 stops?

Verify supply, connector, obstructions, impeller movement, and alarm or protection status using the model-specific troubleshooting data.

What should procurement confirm for 109P0424G3023?

Confirm full suffix, voltage, connector, control signal, bearing, IP rating, certifications, stock, and required delivery date.

在线留言