首页 > 产品 > 按类型 > 轴流风机 > 109P0424H6D19 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

109P0424H6D19 三洋 轴流风机

品牌:
三洋
型号:
109P0424H6D19 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling
类型:
轴流风机
应用行业:
数据中心冷却
产品描述:

109P0424H6D19 addresses servers, UPS systems, and telecom equipment through a 24 VDC DC axial fan platform measuring 40 × 40 × 20 mm. High airflow is highlighted together with a high-static-pressure design. The 40 × 40 × 20 mm format is the primary stated selection detail. Check cabinet ventilation planning cooling specification.

规格书:
109P0424H6D19 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)24
Size(mm)40*40*20

产品特点

High Airflow Design

109P0424H6D19 is intended for dependable forced-air cooling in servers, storage systems and ICT equipment. This SANYO DENKI DC axial fan fits equipment designs where thermal stability affects service continuity.

Engineers should review the model-specific fan curve against filters, grilles and enclosure resistance to confirm the required operating point. For design approval, verify airflow direction, connector details and available control signals. Prototype testing should include the final vents, guards and component loading.

Include filter loading in the airflow margin. It supports a clear fan specification for future servicing. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

应用行业

常见问题

How noisy is 109P0424H6D19?

The supplied row has no noise value. Request model-specific acoustic data when noise control is critical.

What should be checked if 109P0424H6D19 stops?

Verify supply, connector, obstructions, impeller movement, and alarm or protection status using the model-specific troubleshooting data.

What should procurement confirm for 109P0424H6D19?

Confirm full suffix, voltage, connector, control signal, bearing, IP rating, certifications, stock, and required delivery date.

Does 109P0424H6D19 have a pressure rating?

No pressure value is supplied; request the performance curve if static pressure is important.

What equipment is 109P0424H6D19 suited to?

It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.

Can 109P0424H6D19 replace another fan directly?

Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.