The 24 VDC Sanyo Denki 109P0424J3D013 is a DC axial fan sized 40 × 40 × 28 mm for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. 12500 rpm is the model's most prominent operating value. Check acoustic limit assessment installation footprint. Focus: acoustic limit assessment installation footprint.

产品特点

Rated Voltage(V)24
Size(mm)40*40*28
Max.Air Flow(m³/h)27.2
Max.Pressure(Pa)210
Input Power(W)4.32
Speed(rpm)12500
Noise(db)44

产品特点

Efficient Cooling

For servers, storage systems and ICT equipment, the SANYO DENKI 109P0424J3D013 provides DC axial fan cooling in an integration-ready format. It establishes an active air path through restricted equipment spaces.

With up to 27.2 m3/h airflow and 210 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.

Confirm inlet clearance around nearby cables. This improves consistency between prototype and production. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

应用行业

常见问题

What IP protection is documented for 109P0424J3D013?

No exact IP rating is supplied for this model row. Check the current model datasheet before use in water, dust, or oil exposure.

What maintenance does 109P0424J3D013 require?

Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.

Why choose 109P0424J3D013 instead of a standard fan?

Its 24 VDC rating and documented 12500 rpm is the model's most prominent operating value. provide model-specific selection data without relying on unlisted claims.

What supply voltage does 109P0424J3D013 require?

The worksheet lists 24 VDC. Check polarity or AC frequency and the wiring diagram before commissioning.

What should be checked if 109P0424J3D013 stops?

Verify supply, connector, obstructions, impeller movement, and alarm or protection status using the model-specific troubleshooting data.

What bearing type does 109P0424J3D013 use?

The exact bearing is not stated in the supplied row. Confirm it from the complete model suffix and current Sanyo Denki datasheet.