获取报价
首页 > 产品 > 按类型 > 轴流风机 > 109P0512H701 | Sanyo Denki 12VDC 1.2W DC Axial Fan for UPS, server and telecom equipment cooling

109P0512H701 三洋 轴流风机

品牌:
三洋
型号:
109P0512H701 | Sanyo Denki 12VDC 1.2W DC Axial Fan for UPS, server and telecom equipment cooling
类型:
轴流风机
应用行业:
数据中心冷却
产品描述:

Within servers, UPS systems, and telecom equipment, 109P0512H701 provides a 52 × 52 × 15 mm, 12 VDC DC axial fan configuration. High airflow is highlighted together with a high-static-pressure design. The 15.1 m³/h airflow figure supports its stated equipment-cooling role. Check selection criteria review pressure capability.

产品特点

Rated Voltage(V)12
Size(mm)52*52*15
Max.Air Flow(m³/h)15.1
Max.Pressure(Pa)31.8
Input Power(W)1.2
Speed(rpm)4600
Noise(db)27

产品特点

High Airflow Design

SANYO DENKI positions 109P0512H701 as a DC axial fan for servers, storage systems and ICT equipment. It helps equipment designers manage local hot spots where natural convection is insufficient.

Its 15.1 m3/h maximum airflow supports rapid air exchange, while 31.8 Pa pressure capability helps overcome resistance within the finished equipment. For design approval, verify airflow direction, connector details and available control signals. Prototype testing should include the final vents, guards and component loading.

Check startup demand against the power supply. This provides buyers with a traceable selection basis. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

应用行业

常见问题

What should procurement confirm for 109P0512H701?

Confirm full suffix, voltage, connector, control signal, bearing, IP rating, certifications, stock, and required delivery date.

How should 109P0512H701 be matched to an enclosure?

Check its 52 × 52 × 15 mm size, 15.1 m³/h airflow, 31.8 Pa pressure, mounting points, airflow direction, and system resistance.

Is 109P0512H701 suitable for high-reliability cooling?

Evaluate the exact bearing, life, temperature, alarm, and protection data. Correct sizing and clean airflow are also required for reliable operation.

Which application details matter most for 109P0512H701?

Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.

What maintenance does 109P0512H701 require?

Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.

Why choose 109P0512H701 instead of a standard fan?

Its 12 VDC rating and documented the 15.1 m³/h airflow figure supports its stated equipment-cooling role. provide model-specific selection data without relying on unlisted claims.