获取报价
首页 > 产品 > 按类型 > 轴流风机 > 109P0524H7D01 | Sanyo Denki 24VDC 1.2W DC Axial Fan for UPS, server and telecom equipment cooling

109P0524H7D01 三洋 轴流风机

品牌:
三洋
型号:
109P0524H7D01 | Sanyo Denki 24VDC 1.2W DC Axial Fan for UPS, server and telecom equipment cooling
类型:
轴流风机
应用行业:
数据中心冷却
产品描述:

109P0524H7D01 addresses servers, UPS systems, and telecom equipment through a 24 VDC DC axial fan platform measuring 52 × 52 × 15 mm. Series focus: high airflow and pressure. The 15.1 m³/h airflow figure supports its stated equipment-cooling role. Check wiring scheme review static-pressure entry. Focus: wiring scheme review static-pressure entry.

产品特点

Rated Voltage(V)24
Size(mm)52*52*15
Max.Air Flow(m³/h)15.1
Max.Pressure(Pa)31.8
Input Power(W)1.2
Speed(rpm)4600
Noise(db)27

产品特点

High Airflow Design

For servers, storage systems and ICT equipment, the SANYO DENKI 109P0524H7D01 provides DC axial fan cooling in an integration-ready format. It establishes an active air path through restricted equipment spaces.

With up to 15.1 m3/h airflow and 31.8 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. OEM qualification should check startup demand, installation orientation and the exact electrical interface. Installed sound and airflow depend on the surrounding cabinet structure.

Test component temperatures at peak load. This improves consistency between prototype and production. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

应用行业

常见问题

Can 109P0524H7D01 replace another fan directly?

Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.

What maintenance does 109P0524H7D01 require?

Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.

Why choose 109P0524H7D01 instead of a standard fan?

Its 24 VDC rating and documented the 15.1 m³/h airflow figure supports its stated equipment-cooling role. provide model-specific selection data without relying on unlisted claims.

How noisy is 109P0524H7D01?

The worksheet lists 27 dB. Enclosure acoustics, system resistance, and distance can change the installed result.

What speed is listed for 109P0524H7D01?

The listed speed is 4600 rpm. Confirm control conditions and the actual duty point.

Is 109P0524H7D01 easy to install and maintain?

Confirm connector and mounting details, keep the airflow path clear, and isolate power before cleaning or service.