Sanyo Denki 109P0612H701 combines a 60 × 60 × 15 mm DC axial fan platform with a 12 VDC rating for servers, UPS systems, and telecom equipment. The supplied reference emphasizes high static pressure and high airflow. A listed input of 1.08 W is the notable efficiency-related parameter. Selection focus: control interface planning frame geometry.

产品特点

Rated Voltage(V)12
Size(mm)60*60*15
Max.Air Flow(m³/h)23.7
Max.Pressure(Pa)38.2
Input Power(W)1.08
Speed(rpm)4100
Noise(db)32

产品特点

Stable San Ace Fan

The SANYO DENKI 109P0612H701 is a DC axial fan developed for servers, storage systems and ICT equipment. Its directed airflow helps remove heat from densely arranged components and supports predictable equipment temperatures.

Its 23.7 m3/h maximum airflow supports rapid air exchange, while 38.2 Pa pressure capability helps overcome resistance within the finished equipment. For design approval, verify airflow direction, connector details and available control signals. Prototype testing should include the final vents, guards and component loading.

Review airflow direction before design release. This confirms cooling margin before volume production. Confirm the final fan curve in the assembled equipment.

应用行业

常见问题

Does 109P0612H701 have a pressure rating?

The worksheet lists 38.2 Pa. Use the official curve to match it to system resistance.

What certifications apply to 109P0612H701?

The workbook marks it RoHS compliant. Confirm model-specific UL, CSA, TÜV, or other required approvals from official documentation.

Which application details matter most for 109P0612H701?

Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.

What airflow is listed for 109P0612H701?

The worksheet lists 23.7 m³/h. Compare the operating point with system resistance and the official performance curve.

Can 109P0612H701 reduce total operating cost?

Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.

How noisy is 109P0612H701?

The worksheet lists 32 dB. Enclosure acoustics, system resistance, and distance can change the installed result.