The 109R0612M4D01 is a Sanyo Denki 12 VDC, 60 × 60 × 25 mm DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Treat the frame geometry as a primary input to mounting verification. Verify the exact bearing and signal options in the datasheet. Focus: service access planning power demand.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 60*60*25 |
| Max.Air Flow(m³/h) | 21.4 |
| Max.Pressure(Pa) | 19.6 |
| Speed(rpm) | 2600 |
| Noise(db) | 20 |
The SANYO DENKI 109R0612M4D01 is a DC axial fan developed for servers, storage systems and ICT equipment. Its directed airflow helps remove heat from densely arranged components and supports predictable equipment temperatures.
With up to 21.4 m3/h airflow and 19.6 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. Selection should include a system-resistance review, mounting check and harness confirmation. The full model code matters because signal and lead options can differ within a series.
Review airflow direction before design release. The process documents the required installation conditions. Confirm the final fan curve in the assembled equipment.
The San Ace 109R0612M4D01 supports thermal management in server chassis and computing nodes. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. It provides a practical cooling path for OEM integration.
For storage arrays and data appliances, 109R0612M4D01 provides a dedicated forced-air cooling path. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. It provides a practical cooling path for OEM integration.
SANYO DENKI 109R0612M4D01 serves network and other ICT hardware that operate with sustained internal heat. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. It provides a practical cooling path for OEM integration.
The worksheet lists 19.6 Pa. Use the official curve to match it to system resistance.
It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.
Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.
Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.
Availability and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.
Input power is not stated in the supplied row and requires confirmation.

Suited to New Energy, ebm-papst R3G400-FJ75-01 is a 380-480V EC backward-curved centrifugal fan, with a listed pressure capability of 800 Pa. The rating aids system-fit checks. Its documented data supports integration planning.
查看更多
Intended for New Energy, the ebm-papst R3G560-FA28-03 is a 380-480V EC backward-curved centrifugal fan, centered on a listed airflow of 18,535 m³/h. This helps guide installation planning.
查看更多
Selected for New Energy, the ebm-papst R3G500-FA28-03 is a 380-480V EC backward-curved centrifugal fan, distinguished by a listed pressure capability of 794 Pa. It provides a practical sizing reference.
查看更多
In Cleanroom equipment, R3G280-8317084540 is an EC backward-curved centrifugal fan whose documented profile includes 280 mm dimensions for installation planning; the supplied table leaves the rated voltage unspecified.
查看更多
The R3G310-8317083844 serves Cleanroom as an EC backward-curved centrifugal fan, with 310 mm dimensions for installation planning as its clearest supplied attribute. No rated voltage is listed in the provided table.
查看更多
For Cleanroom, R3G400-8317084403 provides an EC backward-curved centrifugal fan format with 400 mm dimensions for installation planning. Rated voltage is not shown in the supplied table and must be checked before selection.
查看更多