获取报价
首页 > 产品 > 按类型 > 轴流风机 > 109R0824G401 | Sanyo Denki 24VDC 4.8W DC Axial Fan for UPS, server and telecom equipment cooling

109R0824G401 三洋 轴流风机

品牌:
三洋
型号:
109R0824G401 | Sanyo Denki 24VDC 4.8W DC Axial Fan for UPS, server and telecom equipment cooling
类型:
轴流风机
应用行业:
数据中心冷却
产品描述:

Sanyo Denki 109R0824G401 is a 24 VDC DC axial fan in a 80 × 80 × 25 mm format for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. 80.4 Pa maximum pressure is the most distinctive duty-point parameter. Check cooling margin validation motor input. Focus: cooling margin validation.

产品特点

Rated Voltage(V)24
Size(mm)80*80*25
Max.Air Flow(m³/h)90
Max.Pressure(Pa)80.4
Input Power(W)4.8
Speed(rpm)4500
Noise(db)40

产品特点

High Airflow Design

SANYO DENKI positions 109R0824G401 as a DC axial fan for servers, storage systems and ICT equipment. It helps equipment designers manage local hot spots where natural convection is insufficient.

Its 90 m3/h maximum airflow supports rapid air exchange, while 80.4 Pa pressure capability helps overcome resistance within the finished equipment. Buyers should confirm the complete suffix, connector, sensor output and control option before ordering. Engineers should validate the operating point with the actual grille and filter.

Measure installed sound in the final cabinet. It also creates a clearer thermal approval record. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

应用行业

常见问题

What equipment is 109R0824G401 suited to?

It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.

What IP protection is documented for 109R0824G401?

No exact IP rating is supplied for this model row. Check the current model datasheet before use in water, dust, or oil exposure.

What maintenance does 109R0824G401 require?

Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.

Why choose 109R0824G401 instead of a standard fan?

Its 24 VDC rating and documented 80.4 pa maximum pressure is the most distinctive duty-point parameter. provide model-specific selection data without relying on unlisted claims.

What supply voltage does 109R0824G401 require?

The worksheet lists 24 VDC. Check polarity or AC frequency and the wiring diagram before commissioning.

Can 109R0824G401 run continuously in a 24/7 system?

Verify the exact bearing, rated life, temperature range, and duty limits. The supplied family description alone does not confirm continuous operation for every suffix.