获取报价
首页 > 产品 > 按类型 > 轴流风机 > 109S005 | Sanyo Denki 100VAC 14/12W AC Axial Fan for automation and control cabinet cooling

109S005 三洋 轴流风机

品牌:
三洋
型号:
109S005 | Sanyo Denki 100VAC 14/12W AC Axial Fan for automation and control cabinet cooling
类型:
轴流风机
应用行业:
自动化
产品描述:

Within servers, UPS systems, and telecom equipment, Sanyo Denki 109S005 operates as a 120 × 120 × 38 mm AC axial fan at 100 VAC. The series cooling function is confirmed; suffix-specific options require datasheet verification. Its 2700/3100 rpm rating defines a lower-speed operating point. Focus: resistance curve checking performance curve.

规格书:
109S005 | Sanyo Denki 100VAC 14/12W AC Axial Fan for automation and control cabinet cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)100
Size(mm)120*120*38
Max.Air Flow(m³/h)141/162
Max.Pressure(Pa)55.9/65.7
Input Power(W)14/12
Speed(rpm)2700/3100
Noise(db)40/43

产品特点

Low Vibration Fan

109S005 is intended for dependable forced-air cooling in automation controls, PLC cabinets and drive systems. This SANYO DENKI AC axial fan fits equipment designs where thermal stability affects service continuity.

The rated peak airflow of 141/162 m3/h combines with 55.9/65.7 Pa pressure capability to support useful flow after installation losses are considered. OEM qualification should check startup demand, installation orientation and the exact electrical interface. Installed sound and airflow depend on the surrounding cabinet structure.

Measure installed sound in the final cabinet. It supports stable operation across the intended load cycle. Confirm the final fan curve in the assembled equipment.

应用行业

常见问题

What should procurement confirm for 109S005?

Confirm full suffix, voltage, connector, control signal, bearing, IP rating, certifications, stock, and required delivery date.

Which specifications define 109S005?

Use rated voltage, 120 × 120 × 38 mm dimensions, 141/162 m³/h airflow, 2700/3100 rpm, and 14/12 W input for preliminary comparison.

What certifications apply to 109S005?

The workbook marks it RoHS compliant. Confirm model-specific UL, CSA, TÜV, or other required approvals from official documentation.

Which application details matter most for 109S005?

Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.

Does 109S005 support PWM speed control?

PWM or sensor functions depend on the exact suffix. Confirm the control lead and interface in the applicable Sanyo Denki datasheet.