首页 > 产品 > 按类型 > 轴流风机 > 9G0624S4002 | Sanyo Denki 24VDC 8.16W DC Axial Fan for UPS, server and telecom equipment cooling

9G0624S4002 三洋 轴流风机

品牌:
三洋
型号:
9G0624S4002 | Sanyo Denki 24VDC 8.16W DC Axial Fan for UPS, server and telecom equipment cooling
类型:
轴流风机
应用行业:
数据中心冷却
产品描述:

Equipment designers serving servers, UPS systems, and telecom equipment can evaluate Sanyo Denki 9G0624S4002, a DC axial fan rated at 24 VDC and sized 60 × 60 × 25 mm. 11000 rpm is the model's most prominent operating value. Treat the acoustic value as a primary input to airflow-path design. Treat bearing and life data as suffix-specific.

规格书:
9G0624S4002 | Sanyo Denki 24VDC 8.16W DC Axial Fan for UPS, server and telecom equipment cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)24
Size(mm)60*60*25
Max.Air Flow(m³/h)82.8
Max.Pressure(Pa)298.9
Input Power(W)8.16
Speed(rpm)11000
Noise(db)53

产品特点

Reliable Fan Cooling

For servers, storage systems and ICT equipment, the SANYO DENKI 9G0624S4002 provides DC axial fan cooling in an integration-ready format. It establishes an active air path through restricted equipment spaces.

A listed maximum airflow of 82.8 m3/h and maximum pressure of 298.9 Pa give engineers a clear basis for matching the fan to enclosure resistance. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.

Qualify performance with the production guard. It also creates a clearer thermal approval record. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

应用行业

常见问题

What speed is listed for 9G0624S4002?

The listed speed is 11000 rpm. Confirm control conditions and the actual duty point.

What should procurement confirm for 9G0624S4002?

Confirm full suffix, voltage, connector, control signal, bearing, IP rating, certifications, stock, and required delivery date.

How should 9G0624S4002 be matched to an enclosure?

Check its 60 × 60 × 25 mm size, 82.8 m³/h airflow, 298.9 Pa pressure, mounting points, airflow direction, and system resistance.

What equipment is 9G0624S4002 suited to?

It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.

Can 9G0624S4002 replace another fan directly?

Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.