Sanyo Denki configures 9G1212H101 for servers, UPS systems, and telecom equipment as a 12 VDC DC axial fan with 120 × 120 × 38 mm dimensions. Its 2600 rpm rating defines a lower-speed operating point. Base service-life planning on the stated catalog specification. Confirm control inputs against the complete ordering code.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 120*120*38 |
| Max.Air Flow(m³/h) | 168.3 |
| Max.Pressure(Pa) | 70.5 |
| Input Power(W) | 4.56 |
| Speed(rpm) | 2600 |
| Noise(db) | 39 |
9G1212H101 brings San Ace DC axial fan cooling to servers, storage systems and ICT equipment. The compact air-moving design suits OEM assemblies that require continuous ventilation around electronic and power components.
With up to 168.3 m3/h airflow and 70.5 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. For design approval, verify airflow direction, connector details and available control signals. Prototype testing should include the final vents, guards and component loading.
Check exhaust separation from the intake zone. This improves consistency between prototype and production. Confirm the final fan curve in the assembled equipment.
The San Ace 9G1212H101 supports thermal management in server chassis and computing nodes. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. The application supports stable equipment service.
For storage arrays and data appliances, 9G1212H101 provides a dedicated forced-air cooling path. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. The application supports stable equipment service.
SANYO DENKI 9G1212H101 serves network and other ICT hardware that operate with sustained internal heat. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. The application supports stable equipment service.
Evaluate the exact bearing, life, temperature, alarm, and protection data. Correct sizing and clean airflow are also required for reliable operation.
Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.
The worksheet lists 168.3 m³/h. Compare the operating point with system resistance and the official performance curve.
Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.
The worksheet lists 39 dB. Enclosure acoustics, system resistance, and distance can change the installed result.
Verify supply, connector, obstructions, impeller movement, and alarm or protection status using the model-specific troubleshooting data.

Aimed at Boiler Systems, the ebm-papst G1G146-BA07-52 is a 24 V EC backward-curved centrifugal fan, for which the table lists a listed pressure capability of 500 Pa. This assists electrical and mechanical review.
查看更多
Integrated into Boiler Systems, the ebm-papst G1G133-DE19-15 is a 24 V EC backward-curved centrifugal fan, specified with a documented 45 W input rating. The rating aids system-fit checks.
查看更多
Suited to Boiler Systems, ebm-papst G1G097-AA05-01 is a 24 V EC backward-curved centrifugal fan, marked by a documented 16 W input rating. It provides a practical sizing reference.
查看更多
Targeting dehumidifiers, G2E140-AL40-01 pairs 230 V operation with a AC centrifugal blower layout. For selection, its most distinctive listed attribute is IP44 protection with thermal-overload protection.
查看更多
In inverter cooling, G2D180-BD18-13 serves as a 400 V AC centrifugal blower. Its standout data point is 840 Pa pressure with IP00 protection. It supports exact-model comparison for OEM sourcing and replacement work.
查看更多
G2D180-BD18-11 is specified as a 400 V AC centrifugal blower for cnc machines. Its selection profile is led by 700 Pa pressure with 2,650 rpm operation. It supports exact-model comparison for OEM sourcing and replacement work.