9G1224A4D01 serves servers, UPS systems, and telecom equipment as a 120 × 120 × 32 mm DC axial fan rated at 24 VDC. Series focus: high airflow and pressure. Its listed airflow of 170 m³/h is the standout performance value. Check enclosure space planning volume-flow figure. Focus: enclosure space planning volume-flow figure.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 120*120*32 |
| Max.Air Flow(m³/h) | 170 |
| Input Power(W) | 5.04 |
| Speed(rpm) | 3150 |
| Noise(db) | 44 |
For servers, storage systems and ICT equipment, the SANYO DENKI 9G1224A4D01 provides DC axial fan cooling in an integration-ready format. It establishes an active air path through restricted equipment spaces.
The specified maximum airflow of 170 m3/h provides a measurable basis for estimating air exchange and selecting the required cooling margin. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.
Review grille loss at the required duty point. It helps maintenance teams plan compatible replacements. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.
9G1224A4D01 is suitable for server chassis and computing nodes. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. It supports reliable OEM equipment cooling. Selection should follow the approved full model code.
The San Ace 9G1224A4D01 supports thermal management in storage arrays and data appliances. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. It supports reliable OEM equipment cooling.
For network and other ICT hardware, 9G1224A4D01 provides a dedicated forced-air cooling path. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. It supports reliable OEM equipment cooling.
Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.
Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.
Availability and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.
The worksheet lists 44 dB. Enclosure acoustics, system resistance, and distance can change the installed result.
The listed speed is 3150 rpm. Confirm control conditions and the actual duty point.

Aimed at Boiler Systems, the ebm-papst G1G146-BA07-52 is a 24 V EC backward-curved centrifugal fan, for which the table lists a listed pressure capability of 500 Pa. This assists electrical and mechanical review.
查看更多
Integrated into Boiler Systems, the ebm-papst G1G133-DE19-15 is a 24 V EC backward-curved centrifugal fan, specified with a documented 45 W input rating. The rating aids system-fit checks.
查看更多
Suited to Boiler Systems, ebm-papst G1G097-AA05-01 is a 24 V EC backward-curved centrifugal fan, marked by a documented 16 W input rating. It provides a practical sizing reference.
查看更多
Targeting dehumidifiers, G2E140-AL40-01 pairs 230 V operation with a AC centrifugal blower layout. For selection, its most distinctive listed attribute is IP44 protection with thermal-overload protection.
查看更多
In inverter cooling, G2D180-BD18-13 serves as a 400 V AC centrifugal blower. Its standout data point is 840 Pa pressure with IP00 protection. It supports exact-model comparison for OEM sourcing and replacement work.
查看更多
G2D180-BD18-11 is specified as a 400 V AC centrifugal blower for cnc machines. Its selection profile is led by 700 Pa pressure with 2,650 rpm operation. It supports exact-model comparison for OEM sourcing and replacement work.
查看更多