首页 > 产品 > 按类型 > 轴流风机 > 9G1224E1D01 | Sanyo Denki 24VDC 8.16W DC Axial Fan for UPS, server and telecom equipment cooling

9G1224E1D01 三洋 轴流风机

品牌:
三洋
型号:
9G1224E1D01 | Sanyo Denki 24VDC 8.16W DC Axial Fan for UPS, server and telecom equipment cooling
类型:
轴流风机
应用行业:
数据中心冷却
产品描述:

Sanyo Denki configures 9G1224E1D01 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 120 × 120 × 38 mm dimensions. 0 Pa maximum pressure is the most distinctive duty-point parameter. Treat the sound level as a primary input to system-resistance review. Confirm environmental protection for the ordered version.

产品特点

Rated Voltage(V)24
Size(mm)120*120*38
Max.Air Flow(m³/h)200.6
Max.Pressure(Pa)0
Input Power(W)8.16
Speed(rpm)3100
Noise(db)46

产品特点

Stable San Ace Fan

SANYO DENKI positions 9G1224E1D01 as a DC axial fan for servers, storage systems and ICT equipment. It helps equipment designers manage local hot spots where natural convection is insufficient.

With up to 200.6 m3/h airflow and 0 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. Buyers should confirm the complete suffix, connector, sensor output and control option before ordering. Engineers should validate the operating point with the actual grille and filter.

Assess vibration transfer into enclosure panels. This step reduces uncertainty during equipment qualification. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

应用行业

常见问题

Is 9G1224E1D01 suitable for high-reliability cooling?

Evaluate the exact bearing, life, temperature, alarm, and protection data. Correct sizing and clean airflow are also required for reliable operation.

What IP protection is documented for 9G1224E1D01?

No exact IP rating is supplied for this model row. Check the current model datasheet before use in water, dust, or oil exposure.

What maintenance does 9G1224E1D01 require?

Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.

Can 9G1224E1D01 reduce total operating cost?

Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.

How noisy is 9G1224E1D01?

The worksheet lists 46 dB. Enclosure acoustics, system resistance, and distance can change the installed result.

What should be checked if 9G1224E1D01 stops?

Verify supply, connector, obstructions, impeller movement, and alarm or protection status using the model-specific troubleshooting data.