首页 > 产品 > 按类型 > 轴流风机 > 9G1224G1D011 | Sanyo Denki 24VDC 12W DC Axial Fan for UPS, server and telecom equipment cooling

9G1224G1D011 三洋 轴流风机

品牌:
三洋
型号:
9G1224G1D011 | Sanyo Denki 24VDC 12W DC Axial Fan for UPS, server and telecom equipment cooling
类型:
轴流风机
应用行业:
数据中心冷却
产品描述:

For servers, UPS systems, and telecom equipment, 9G1224G1D011 combines 24 VDC operation with a 120 × 120 × 38 mm DC axial fan design. Series focus: high airflow and pressure. Its listed airflow of 233 m³/h is the standout performance value. Check control interface planning system interface. Focus: control interface planning system interface.

产品特点

Rated Voltage(V)24
Size(mm)120*120*38
Max.Air Flow(m³/h)233
Input Power(W)12
Speed(rpm)3600
Noise(db)49

产品特点

Efficient Cooling

For servers, storage systems and ICT equipment, the SANYO DENKI 9G1224G1D011 provides DC axial fan cooling in an integration-ready format. It establishes an active air path through restricted equipment spaces.

The specified maximum airflow of 233 m3/h provides a measurable basis for estimating air exchange and selecting the required cooling margin. For design approval, verify airflow direction, connector details and available control signals. Prototype testing should include the final vents, guards and component loading.

Check startup demand against the power supply. It helps engineering and procurement use one specification. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

应用行业

常见问题

Does 9G1224G1D011 have a pressure rating?

No pressure value is supplied; request the performance curve if static pressure is important.

What equipment is 9G1224G1D011 suited to?

It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.

What IP protection is documented for 9G1224G1D011?

No exact IP rating is supplied for this model row. Check the current model datasheet before use in water, dust, or oil exposure.

What airflow is listed for 9G1224G1D011?

The worksheet lists 233 m³/h. Compare the operating point with system resistance and the official performance curve.

Can 9G1224G1D011 reduce total operating cost?

Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.

What input power is listed for 9G1224G1D011?

The worksheet lists 12 W. Check supply capacity and operating conditions before commissioning.