首页 > 产品 > 按类型 > 轴流风机 > 9GA0412H7001 | Sanyo Denki 12VDC 0.72W DC Axial Fan for UPS, server and telecom equipment cooling

9GA0412H7001 三洋 轴流风机

品牌:
三洋
型号:
9GA0412H7001 | Sanyo Denki 12VDC 0.72W DC Axial Fan for UPS, server and telecom equipment cooling
类型:
轴流风机
应用行业:
数据中心冷却
产品描述:

The 12 VDC Sanyo Denki 9GA0412H7001 is a DC axial fan sized 40 × 40 × 15 mm for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. A listed input of 0.72 W is the notable efficiency-related parameter. Selection focus: cooling margin validation duty-point values.

规格书:
9GA0412H7001 | Sanyo Denki 12VDC 0.72W DC Axial Fan for UPS, server and telecom equipment cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)12
Size(mm)40*40*15
Max.Air Flow(m³/h)12.07
Max.Pressure(Pa)59.8
Input Power(W)0.72
Speed(rpm)7300
Noise(db)28

产品特点

Efficient Cooling

9GA0412H7001 brings San Ace DC axial fan cooling to servers, storage systems and ICT equipment. The compact air-moving design suits OEM assemblies that require continuous ventilation around electronic and power components.

Its 12.07 m3/h maximum airflow supports rapid air exchange, while 59.8 Pa pressure capability helps overcome resistance within the finished equipment. OEM qualification should check startup demand, installation orientation and the exact electrical interface. Installed sound and airflow depend on the surrounding cabinet structure.

Keep the impeller path clear of wiring. The review links cooling performance to the approved BOM. Confirm the final fan curve in the assembled equipment.

应用行业

常见问题

What certifications apply to 9GA0412H7001?

The workbook marks it RoHS compliant. Confirm model-specific UL, CSA, TÜV, or other required approvals from official documentation.

What IP protection is documented for 9GA0412H7001?

The reference lists IP20. Confirm that the exact ordered suffix carries the required environmental rating.

What maintenance does 9GA0412H7001 require?

Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.

What is the lead time for 9GA0412H7001?

Availability and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.

What input power is listed for 9GA0412H7001?

The worksheet lists 0.72 W. Check supply capacity and operating conditions before commissioning.

Can 9GA0412H7001 run continuously in a 24/7 system?

Verify the exact bearing, rated life, temperature range, and duty limits. The supplied family description alone does not confirm continuous operation for every suffix.