获取报价
首页 > 产品 > 按类型 > 轴流风机 > 9GA0424P3J001 | Sanyo Denki 24VDC 6.48W DC Axial Fan for UPS, server and telecom equipment cooling

9GA0424P3J001 三洋 轴流风机

品牌:
三洋
型号:
9GA0424P3J001 | Sanyo Denki 24VDC 6.48W DC Axial Fan for UPS, server and telecom equipment cooling
类型:
轴流风机
应用行业:
数据中心冷却
产品描述:

A 40 × 40 × 28 mm frame and 24 VDC rating define 9GA0424P3J001, a DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. 18000 rpm is the model's most prominent operating value. Check power budget review volume-flow figure. Focus: power budget review.

规格书:
9GA0424P3J001 | Sanyo Denki 24VDC 6.48W DC Axial Fan for UPS, server and telecom equipment cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)24
Size(mm)40*40*28
Max.Air Flow(m³/h)40.29
Max.Pressure(Pa)535
Input Power(W)6.48
Speed(rpm)18000
Noise(db)54

产品特点

Efficient Cooling

The San Ace 9GA0424P3J001 serves servers, storage systems and ICT equipment as a DC axial fan. Its airflow supports heat transfer from internal devices toward cabinet or chassis exhaust openings.

Its 40.29 m3/h maximum airflow supports rapid air exchange, while 535 Pa pressure capability helps overcome resistance within the finished equipment. OEM qualification should check startup demand, installation orientation and the exact electrical interface. Installed sound and airflow depend on the surrounding cabinet structure.

Check exhaust separation from the intake zone. It helps maintenance teams plan compatible replacements. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

应用行业

常见问题

Why choose 9GA0424P3J001 instead of a standard fan?

Its 24 VDC rating and documented 18000 rpm is the model's most prominent operating value. provide model-specific selection data without relying on unlisted claims.

What input power is listed for 9GA0424P3J001?

The worksheet lists 6.48 W. Check supply capacity and operating conditions before commissioning.

What should be checked if 9GA0424P3J001 stops?

Verify supply, connector, obstructions, impeller movement, and alarm or protection status using the model-specific troubleshooting data.

What bearing type does 9GA0424P3J001 use?

The exact bearing is not stated in the supplied row. Confirm it from the complete model suffix and current Sanyo Denki datasheet.

How should 9GA0424P3J001 be matched to an enclosure?

Check its 40 × 40 × 28 mm size, 40.29 m³/h airflow, 535 Pa pressure, mounting points, airflow direction, and system resistance.

What equipment is 9GA0424P3J001 suited to?

It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.

在线留言