首页 > 产品 > 按类型 > 轴流风机 > 9GA0824H7D001 | Sanyo Denki 24VDC 1.2W DC Axial Fan for UPS, server and telecom equipment cooling

9GA0824H7D001 三洋 轴流风机

品牌:
三洋
型号:
9GA0824H7D001 | Sanyo Denki 24VDC 1.2W DC Axial Fan for UPS, server and telecom equipment cooling
类型:
轴流风机
应用行业:
数据中心冷却
产品描述:

Sanyo Denki configures 9GA0824H7D001 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 80 × 80 × 15 mm dimensions. A listed input of 1.2 W is the notable efficiency-related parameter. During duty-point matching, compare the model's duty-point values. Verify the exact bearing and signal options in the datasheet.

规格书:
9GA0824H7D001 | Sanyo Denki 24VDC 1.2W DC Axial Fan for UPS, server and telecom equipment cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)24
Size(mm)80*80*15
Max.Air Flow(m³/h)52.7
Max.Pressure(Pa)32.4
Input Power(W)1.2
Speed(rpm)3800
Noise(db)29

产品特点

Low Vibration Fan

For servers, storage systems and ICT equipment, the SANYO DENKI 9GA0824H7D001 provides DC axial fan cooling in an integration-ready format. It establishes an active air path through restricted equipment spaces.

The rated peak airflow of 52.7 m3/h combines with 32.4 Pa pressure capability to support useful flow after installation losses are considered. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.

Confirm inlet clearance around nearby cables. The review links cooling performance to the approved BOM. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

应用行业

常见问题

Can 9GA0824H7D001 replace another fan directly?

Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.

What airflow is listed for 9GA0824H7D001?

The worksheet lists 52.7 m³/h. Compare the operating point with system resistance and the official performance curve.

What is the lead time for 9GA0824H7D001?

Availability and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.

What supply voltage does 9GA0824H7D001 require?

The worksheet lists 24 VDC. Check polarity or AC frequency and the wiring diagram before commissioning.

What should be checked if 9GA0824H7D001 stops?

Verify supply, connector, obstructions, impeller movement, and alarm or protection status using the model-specific troubleshooting data.