获取报价
首页 > 产品 > 按类型 > 轴流风机 > 9GA0824P1S61 | Sanyo Denki 24VDC 11.28W DC Axial Fan for UPS, server and telecom equipment cooling

9GA0824P1S61 三洋 轴流风机

品牌:
三洋
型号:
9GA0824P1S61 | Sanyo Denki 24VDC 11.28W DC Axial Fan for UPS, server and telecom equipment cooling
类型:
轴流风机
应用行业:
数据中心冷却
产品描述:

For thermal management in servers, UPS systems, and telecom equipment, the 9GA0824P1S61 provides a 24 VDC DC axial fan configuration measuring 80 × 80 × 38 mm. 480 Pa maximum pressure is the most distinctive duty-point parameter. Base cooling-margin review on the stated electrical load. Confirm environmental protection for the ordered version.

规格书:
9GA0824P1S61 | Sanyo Denki 24VDC 11.28W DC Axial Fan for UPS, server and telecom equipment cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)24
Size(mm)80*80*38
Max.Air Flow(m³/h)156
Max.Pressure(Pa)480
Input Power(W)11.28
Speed(rpm)9550
Noise(db)59

产品特点

High Airflow Design

9GA0824P1S61 brings San Ace DC axial fan cooling to servers, storage systems and ICT equipment. The compact air-moving design suits OEM assemblies that require continuous ventilation around electronic and power components.

Its 156 m3/h maximum airflow supports rapid air exchange, while 480 Pa pressure capability helps overcome resistance within the finished equipment. Selection should include a system-resistance review, mounting check and harness confirmation. The full model code matters because signal and lead options can differ within a series.

Qualify performance with the production guard. This confirms cooling margin before volume production. Confirm the final fan curve in the assembled equipment.

应用行业

常见问题

What should procurement confirm for 9GA0824P1S61?

Confirm full suffix, voltage, connector, control signal, bearing, IP rating, certifications, stock, and required delivery date.

Does 9GA0824P1S61 have a pressure rating?

The worksheet lists 480 Pa. Use the official curve to match it to system resistance.

What equipment is 9GA0824P1S61 suited to?

It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.

Can 9GA0824P1S61 replace another fan directly?

Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.

What airflow is listed for 9GA0824P1S61?

The worksheet lists 156 m³/h. Compare the operating point with system resistance and the official performance curve.

Why choose 9GA0824P1S61 instead of a standard fan?

Its 24 VDC rating and documented 480 pa maximum pressure is the most distinctive duty-point parameter. provide model-specific selection data without relying on unlisted claims.

在线留言