首页 > 产品 > 按类型 > 轴流风机 > 9RA0912P1J001 | Sanyo Denki 12VDC 14.9W DC Axial Fan for UPS, server and telecom equipment cooling

9RA0912P1J001 三洋 轴流风机

品牌:
三洋
型号:
9RA0912P1J001 | Sanyo Denki 12VDC 14.9W DC Axial Fan for UPS, server and telecom equipment cooling
类型:
轴流风机
应用行业:
数据中心冷却
产品描述:

The 12 VDC Sanyo Denki 9RA0912P1J001 is a DC axial fan sized 92 × 92 × 38 mm for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. 14.9 W input is the defining electrical-load figure. Check control interface planning cooling specification. Focus: control interface planning.

规格书:
9RA0912P1J001 | Sanyo Denki 12VDC 14.9W DC Axial Fan for UPS, server and telecom equipment cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)12
Size(mm)92*92*38
Max.Air Flow(m³/h)198.9
Max.Pressure(Pa)192
Input Power(W)14.9
Speed(rpm)6400
Noise(db)50

产品特点

Low Vibration Fan

9RA0912P1J001 is intended for dependable forced-air cooling in servers, storage systems and ICT equipment. This SANYO DENKI DC axial fan fits equipment designs where thermal stability affects service continuity.

The rated peak airflow of 198.9 m3/h combines with 192 Pa pressure capability to support useful flow after installation losses are considered. Buyers should confirm the complete suffix, connector, sensor output and control option before ordering. Engineers should validate the operating point with the actual grille and filter.

Review grille loss at the required duty point. It also creates a clearer thermal approval record. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

应用行业

常见问题

Is 9RA0912P1J001 easy to install and maintain?

Confirm connector and mounting details, keep the airflow path clear, and isolate power before cleaning or service.

Which specifications define 9RA0912P1J001?

Use rated voltage, 92 × 92 × 38 mm dimensions, 198.9 m³/h airflow, 6400 rpm, and 14.9 W input for preliminary comparison.

What certifications apply to 9RA0912P1J001?

The workbook marks it RoHS compliant. Confirm model-specific UL, CSA, TÜV, or other required approvals from official documentation.

Which application details matter most for 9RA0912P1J001?

Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.

What maintenance does 9RA0912P1J001 require?

Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.