获取报价
首页 > 产品 > 按类型 > 轴流风机 > 9S0912L402 | Sanyo Denki 12VDC DC Axial Fan for UPS, server and telecom equipment cooling

9S0912L402 三洋 轴流风机

品牌:
三洋
型号:
9S0912L402 | Sanyo Denki 12VDC DC Axial Fan for UPS, server and telecom equipment cooling
类型:
轴流风机
应用行业:
数据中心冷却
产品描述:

Within servers, UPS systems, and telecom equipment, 9S0912L402 provides a 92 × 92 × 25 mm, 12 VDC DC axial fan configuration. High airflow is highlighted together with a high-static-pressure design. A listed noise figure of 17 dB is the key differentiating parameter. Check selection criteria review sound level. Focus: selection criteria review.

规格书:
9S0912L402 | Sanyo Denki 12VDC DC Axial Fan for UPS, server and telecom equipment cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)12
Size(mm)92*92*25
Max.Air Flow(m³/h)49.2
Max.Pressure(Pa)13.2
Speed(rpm)1750
Noise(db)17

产品特点

High Airflow Design

9S0912L402 is intended for dependable forced-air cooling in servers, storage systems and ICT equipment. This SANYO DENKI DC axial fan fits equipment designs where thermal stability affects service continuity.

With up to 49.2 m3/h airflow and 13.2 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. Selection should include a system-resistance review, mounting check and harness confirmation. The full model code matters because signal and lead options can differ within a series.

Test component temperatures at peak load. It helps maintenance teams plan compatible replacements. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

应用行业

常见问题

What should procurement confirm for 9S0912L402?

Confirm full suffix, voltage, connector, control signal, bearing, IP rating, certifications, stock, and required delivery date.

How should 9S0912L402 be matched to an enclosure?

Check its 92 × 92 × 25 mm size, 49.2 m³/h airflow, 13.2 Pa pressure, mounting points, airflow direction, and system resistance.

What certifications apply to 9S0912L402?

The workbook marks it RoHS compliant. Confirm model-specific UL, CSA, TÜV, or other required approvals from official documentation.

Which application details matter most for 9S0912L402?

Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.

What airflow is listed for 9S0912L402?

The worksheet lists 49.2 m³/h. Compare the operating point with system resistance and the official performance curve.

Why choose 9S0912L402 instead of a standard fan?

Its 12 VDC rating and documented a listed noise figure of 17 db is the key differentiating parameter. provide model-specific selection data without relying on unlisted claims.