获取报价
首页 > 产品 > 按类型 > 轴流风机 > 9S0924M4D01 | Sanyo Denki 24VDC 1.68W DC Axial Fan for UPS, server and telecom equipment cooling

9S0924M4D01 三洋 轴流风机

品牌:
三洋
型号:
9S0924M4D01 | Sanyo Denki 24VDC 1.68W DC Axial Fan for UPS, server and telecom equipment cooling
类型:
轴流风机
应用行业:
数据中心冷却
产品描述:

9S0924M4D01 addresses servers, UPS systems, and telecom equipment through a 24 VDC DC axial fan platform measuring 92 × 92 × 25 mm. Series focus: high airflow and pressure. A listed noise figure of 22 dB is the key differentiating parameter. Check lifecycle requirement review supply requirement. Focus: lifecycle requirement review.

规格书:
9S0924M4D01 | Sanyo Denki 24VDC 1.68W DC Axial Fan for UPS, server and telecom equipment cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)24
Size(mm)92*92*25
Max.Air Flow(m³/h)63.6
Max.Pressure(Pa)21.7
Input Power(W)1.68
Speed(rpm)2250
Noise(db)22

产品特点

Efficient Cooling

The San Ace 9S0924M4D01 serves servers, storage systems and ICT equipment as a DC axial fan. Its airflow supports heat transfer from internal devices toward cabinet or chassis exhaust openings.

With up to 63.6 m3/h airflow and 21.7 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. Buyers should confirm the complete suffix, connector, sensor output and control option before ordering. Engineers should validate the operating point with the actual grille and filter.

Include filter loading in the airflow margin. It helps maintenance teams plan compatible replacements. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

应用行业

常见问题

Can 9S0924M4D01 replace another fan directly?

Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.

What airflow is listed for 9S0924M4D01?

The worksheet lists 63.6 m³/h. Compare the operating point with system resistance and the official performance curve.

Why choose 9S0924M4D01 instead of a standard fan?

Its 24 VDC rating and documented a listed noise figure of 22 db is the key differentiating parameter. provide model-specific selection data without relying on unlisted claims.

How noisy is 9S0924M4D01?

The worksheet lists 22 dB. Enclosure acoustics, system resistance, and distance can change the installed result.

What should be checked if 9S0924M4D01 stops?

Verify supply, connector, obstructions, impeller movement, and alarm or protection status using the model-specific troubleshooting data.

What should procurement confirm for 9S0924M4D01?

Confirm full suffix, voltage, connector, control signal, bearing, IP rating, certifications, stock, and required delivery date.