9SG1224H101 addresses servers, UPS systems, and telecom equipment through a 24 VDC DC axial fan platform measuring 119 × 119 × 38 mm. High airflow is highlighted together with a high-static-pressure design. Its listed airflow of 238.8 m³/h is the standout performance value. Check control interface planning motor input.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 119*119*38 |
| Max.Air Flow(m³/h) | 238.8 |
| Max.Pressure(Pa) | 127 |
| Input Power(W) | 11 |
| Speed(rpm) | 3400 |
| Noise(db) | 48 |
9SG1224H101 brings San Ace DC axial fan cooling to servers, storage systems and ICT equipment. The compact air-moving design suits OEM assemblies that require continuous ventilation around electronic and power components.
With up to 238.8 m3/h airflow and 127 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. Selection should include a system-resistance review, mounting check and harness confirmation. The full model code matters because signal and lead options can differ within a series.
Confirm the operating environment for the suffix. It gives integrators a practical acceptance criterion. Confirm the final fan curve in the assembled equipment.
The San Ace 9SG1224H101 supports thermal management in server chassis and computing nodes. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. It provides a practical cooling path for OEM integration.
For storage arrays and data appliances, 9SG1224H101 provides a dedicated forced-air cooling path. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. It provides a practical cooling path for OEM integration.
SANYO DENKI 9SG1224H101 serves network and other ICT hardware that operate with sustained internal heat. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. It provides a practical cooling path for OEM integration.
Confirm connector and mounting details, keep the airflow path clear, and isolate power before cleaning or service.
Use rated voltage, 119 × 119 × 38 mm dimensions, 238.8 m³/h airflow, 3400 rpm, and 11 W input for preliminary comparison.
Evaluate the exact bearing, life, temperature, alarm, and protection data. Correct sizing and clean airflow are also required for reliable operation.
Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.
The worksheet lists 238.8 m³/h. Compare the operating point with system resistance and the official performance curve.
Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.