首页 > 产品 > 按类型 > 轴流风机 > GF80382BX-10000-ADP | SUNON 24V 39.12W 80x80x38mm 225.8m3/h DC Axial Fan for Data Center Cooling

GF80382BX-10000-ADP SUNON 轴流风机

品牌:
SUNON
型号:
GF80382BX-10000-ADP | SUNON 24V 39.12W 80x80x38mm 225.8m3/h DC Axial Fan for Data Center Cooling
类型:
轴流风机
应用行业:
数据中心冷却
产品描述:

For airflow duties across servers and data-center electronics, the GF80382BX-10000-ADP provides a 24 VDC DC axial fan configuration measuring 80 × 80 × 38 mm. Up to 225.8 m³/h is its most prominent listed performance figure. The recorded application data should guide fan selection. Use current model documentation to validate protection choices.

规格书:
GF80382BX-10000-ADP | SUNON 24V 39.12W 80x80x38mm 225.8m3/h DC Axial Fan for Data Center Cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)24
Size(mm)80x80x38mm
Max.Air Flow(m³/h)225.8
Max.Pressure(Pa)448.4
Input Power(W)39.12
Speed(rpm)10000
Noise(db)65.2

产品特点

High Airflow Cooling

The SUNON GF80382BX-10000-ADP positions a DC brushless axial fan for server and data-center equipment. Its airflow path supports heat removal from enclosed components and toward the equipment exhaust.

The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market.

To integrate GF80382BX-10000-ADP effectively, review outlet geometry at equipment level and arrange thermal-load testing during sourcing review. Confirmed system compatibility supports stable cooling and repeatable procurement. Preserve a clear discharge region to avoid unnecessary downstream turbulence. The final assembly should be tested under its expected thermal load.

应用行业

常见问题

What noise data are available for GF80382BX-10000-ADP?

The worksheet lists 65.2 dB. Installation distance, airflow resistance, and enclosure acoustics can change the measured result.

What airflow value is listed for GF80382BX-10000-ADP?

The worksheet lists up to 225.8 m³/h. Verify the operating point against system resistance.

Does GF80382BX-10000-ADP have a documented pressure rating?

Yes. The worksheet lists up to 448.4 Pa; compare it with the system curve.

Which performance figures define GF80382BX-10000-ADP?

Use the listed voltage, size, 225.8 m³/h airflow, 10000 rpm, and 39.12 W input for preliminary comparison.

Can GF80382BX-10000-ADP serve high-reliability cooling systems?

Assess reliability from the exact bearing, temperature, protection, and life data. The supplied series note alone does not confirm every suffix-specific option.