获取报价
首页 > 产品 > 按类型 > 轴流风机 > MF25060V1-10000-A99 | SUNON 5V 0.58W 25x25x6mm 5.1m3/h DC Axial Fan for Telecommunications

MF25060V1-10000-A99 SUNON 轴流风机

品牌:
SUNON
型号:
MF25060V1-10000-A99 | SUNON 5V 0.58W 25x25x6mm 5.1m3/h DC Axial Fan for Telecommunications
类型:
轴流风机
应用行业:
电信
产品描述:

The MF25060V1-10000-A99 is SUNON's 5 VDC, 25 × 25 × 6 mm DC axial fan option for telecom cabinets and network equipment. Its 5.1 m³/h airflow rating suits the stated equipment-cooling role. Treat the power demand as a primary input to maintenance preparation. Confirm temperature and service-life limits from current data.

规格书:
MF25060V1-10000-A99 | SUNON 5V 0.58W 25x25x6mm 5.1m3/h DC Axial Fan for Telecommunications 规格书 (Pdf)

产品特点

Rated Voltage(V)5
Size(mm)25x25x6mm
Max.Air Flow(m³/h)5.1
Max.Pressure(Pa)57.3
Input Power(W)0.58
Speed(rpm)13000
Noise(db)24.8

产品特点

MagLev Cooling

Equipment builders can integrate SUNON MF25060V1-10000-A99, a DC brushless axial fan, into telecommunications equipment. The design supplies the air movement required to carry component heat out of confined spaces.

The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market.

Design approval for MF25060V1-10000-A99 should cover cable routing together with airflow mapping within OEM validation. This creates a practical link between thermal validation, purchasing documentation and future servicing. Review circulation around the components most sensitive to heat. The final assembly should be tested under its expected thermal load.

应用行业

常见问题

Can MF25060V1-10000-A99 serve high-reliability cooling systems?

Assess reliability from the exact bearing, temperature, protection, and life data. The supplied series note alone does not confirm every suffix-specific option.

How is MF25060V1-10000-A99 electrically connected?

The supplied row does not state the connector or lead configuration. Follow the model-specific wiring drawing.

What maintenance is recommended for MF25060V1-10000-A99?

Inspect for dust, blocked airflow, abnormal noise, loose mounting, and wiring damage. Isolate power before cleaning or service.

How can MF25060V1-10000-A99 affect operating cost?

Compare its listed 0.58 W input with the required airflow and run time. Total savings depend on the complete system duty point.

What noise data are available for MF25060V1-10000-A99?

The worksheet lists 24.8 dB. Installation distance, airflow resistance, and enclosure acoustics can change the measured result.

What airflow value is listed for MF25060V1-10000-A99?

The worksheet lists up to 5.1 m³/h. Verify the operating point against system resistance.