获取报价
首页 > 产品 > 按类型 > 轴流风机 > MF40100V2-1000U-G99 | SUNON 5V 0.47W 40x40x10mm 11.8m3/h DC Axial Fan for Telecommunications

MF40100V2-1000U-G99 SUNON 轴流风机

品牌:
SUNON
型号:
MF40100V2-1000U-G99 | SUNON 5V 0.47W 40x40x10mm 11.8m3/h DC Axial Fan for Telecommunications
类型:
轴流风机
应用行业:
电信
产品描述:

SUNON configures MF40100V2-1000U-G99 as a 40 × 40 × 10 mm DC axial fan for telecom cabinets and network equipment, operating at 5 VDC. A listed input of 0.47 W is the model's notable electrical characteristic. Treat the performance curve as a primary input to maintenance preparation. Confirm temperature and service-life limits from current data.

规格书:
MF40100V2-1000U-G99 | SUNON 5V 0.47W 40x40x10mm 11.8m3/h DC Axial Fan for Telecommunications 规格书 (Pdf)

产品特点

Rated Voltage(V)5
Size(mm)40x40x10
Max.Air Flow(m³/h)11.8
Max.Pressure(Pa)29.9
Input Power(W)0.47
Speed(rpm)5800
Noise(db)20.6

产品特点

MagLev Cooling

SUNON MF40100V2-1000U-G99 brings active air movement to telecommunications equipment. This DC brushless axial fan helps equipment designers control thermal conditions around densely arranged parts.

SUNON's DC product line is developed around MagLev motor technology, supporting low-friction rotation, energy-conscious operation and long service life in compact formats.

A dependable MF40100V2-1000U-G99 installation starts with a review of exhaust separation. Complete power-budget review within OEM validation to confirm compatibility, operating margin and the information needed for repeat orders. Separate discharge air from the intake path inside the finished enclosure. The final assembly should be tested under its expected thermal load.

应用行业

常见问题

How should MF40100V2-1000U-G99 be matched to an enclosure?

Review its 40 × 40 × 10 mm size, 11.8 m³/h airflow, 29.9 Pa pressure, system resistance, and available mounting space.

Can MF40100V2-1000U-G99 serve high-reliability cooling systems?

Assess reliability from the exact bearing, temperature, protection, and life data. The supplied series note alone does not confirm every suffix-specific option.

Which selection data still require confirmation for MF40100V2-1000U-G99?

Confirm any missing bearing, connector, control, IP rating, life, certification, and performance-curve details for the complete part number.

What maintenance is recommended for MF40100V2-1000U-G99?

Inspect for dust, blocked airflow, abnormal noise, loose mounting, and wiring damage. Isolate power before cleaning or service.

How can MF40100V2-1000U-G99 affect operating cost?

Compare its listed 0.47 W input with the required airflow and run time. Total savings depend on the complete system duty point.