获取报价
首页 > 产品 > 按类型 > 鼓风机 > MF50201V1-1Q030-S99 | SUNON 12V 1.49W 50x50x20mm DC Centrifugal Blower for Data Center Cooling

MF50201V1-1Q030-S99 SUNON 鼓风机

品牌:
SUNON
型号:
MF50201V1-1Q030-S99 | SUNON 12V 1.49W 50x50x20mm DC Centrifugal Blower for Data Center Cooling
类型:
鼓风机
应用行业:
数据中心冷却
产品描述:

Configured for servers and data-center electronics, SUNON MF50201V1-1Q030-S99 is a 12 VDC DC blower in a 50 × 50 × 20 mm frame. Its 9.9 m³/h airflow rating suits the stated equipment-cooling role. Treat the cooling specification as a primary input to controller selection. Treat bearing and life data as suffix-specific.

规格书:
MF50201V1-1Q030-S99 | SUNON 12V 1.49W 50x50x20mm DC Centrifugal Blower for Data Center Cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)12
Size(mm)50x50x20mm
Max.Air Flow(m³/h)9.9
Max.Pressure(Pa)164.4
Input Power(W)1.49
Speed(rpm)5300
Noise(db)34.8

产品特点

Directed Air Cooling

The SUNON MF50201V1-1Q030-S99 positions a DC brushless blower for server and data-center equipment. Its airflow path supports heat removal from enclosed components and toward the equipment exhaust.

The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market. Correct airflow direction and inlet clearance help translate the documented operating point into reliable equipment-level cooling.

A dependable MF50201V1-1Q030-S99 installation starts with a review of exhaust separation. Complete thermal-load testing before ordering to confirm compatibility, operating margin and the information needed for repeat orders. Separate discharge air from the intake path inside the finished enclosure.

应用行业

常见问题

Is MF50201V1-1Q030-S99 compatible with a replacement fan?

Match voltage, dimensions, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.

Why choose MF50201V1-1Q030-S99 over a general cooling fan?

Its documented 12 VDC rating and its 9.9 m³/h airflow rating suits the stated equipment-cooling role. allow comparison with the required duty point without assuming unlisted options.

What voltage is required by MF50201V1-1Q030-S99?

The listed rating is 12 VDC. Verify polarity or mains frequency, wiring, and protection before commissioning.

What should be checked if MF50201V1-1Q030-S99 stops?

Verify supply, wiring, obstructions, impeller movement, and protection status. Use the model datasheet before replacement or repair.

Does MF50201V1-1Q030-S99 have a documented pressure rating?

Yes. The worksheet lists up to 164.4 Pa; compare it with the system curve.

在线留言