获取报价
首页 > 产品 > 按类型 > 轴流风机 > MF60101V1-10000-A99 | SUNON 12V 1.3W 60x60x10mm 27.7m3/h DC Axial Fan for Telecommunications

MF60101V1-10000-A99 SUNON 轴流风机

品牌:
SUNON
型号:
MF60101V1-10000-A99 | SUNON 12V 1.3W 60x60x10mm 27.7m3/h DC Axial Fan for Telecommunications
类型:
轴流风机
应用行业:
电信
产品描述:

Engineered for telecom cabinets and network equipment, SUNON MF60101V1-10000-A99 is a 12 VDC DC axial fan in a 60 × 60 × 10 mm frame. 29.9 Pa maximum pressure is the standout documented duty-point value. For duty-point matching, start with the supplied model record. Validate approvals and protection at complete-part-number level.

规格书:
MF60101V1-10000-A99 | SUNON 12V 1.3W 60x60x10mm 27.7m3/h DC Axial Fan for Telecommunications 规格书 (Pdf)

产品特点

Rated Voltage(V)12
Size(mm)60x60x10mm
Max.Air Flow(m³/h)27.7
Max.Pressure(Pa)29.9
Input Power(W)1.3
Speed(rpm)4000
Noise(db)28.5

产品特点

MagLev Cooling

SUNON MF60101V1-10000-A99 brings active air movement to telecommunications equipment. This DC brushless axial fan helps equipment designers control thermal conditions around densely arranged parts.

SUNON's DC product line is developed around MagLev motor technology, supporting low-friction rotation, energy-conscious operation and long service life in compact formats.

The final MF60101V1-10000-A99 selection should consider connector reach as part of the installation layout. Finishing duty-point validation before design lock helps reduce integration uncertainty and supports reliable equipment cooling. Confirm that the mating lead reaches without tension or sharp bending. The final assembly should be tested under its expected thermal load.

应用行业

常见问题

Does MF60101V1-10000-A99 have a documented pressure rating?

Yes. The worksheet lists up to 29.9 Pa; compare it with the system curve.

How should MF60101V1-10000-A99 be matched to an enclosure?

Review its 60 × 60 × 10 mm size, 27.7 m³/h airflow, 29.9 Pa pressure, system resistance, and available mounting space.

What certification information is listed for MF60101V1-10000-A99?

The workbook marks the product as RoHS compliant. Confirm UL, TUV, VDE, or other project-specific approvals for the exact suffix.

How is MF60101V1-10000-A99 electrically connected?

The supplied row does not state the connector or lead configuration. Follow the model-specific wiring drawing.

Does MF60101V1-10000-A99 support speed control?

Speed-control capability is not stated for this complete part number. Confirm the signal and controller requirements before use.

在线留言