获取报价
首页 > 产品 > 按类型 > 轴流风机 > MF60101V1-1000U-G99 | SUNON 12V 1.3W 60x60x10mm 27.7m3/h DC Axial Fan for Telecommunications

MF60101V1-1000U-G99 SUNON 轴流风机

品牌:
SUNON
型号:
MF60101V1-1000U-G99 | SUNON 12V 1.3W 60x60x10mm 27.7m3/h DC Axial Fan for Telecommunications
类型:
轴流风机
应用行业:
电信
产品描述:

SUNON MF60101V1-1000U-G99 combines a 60 × 60 × 10 mm DC axial fan platform with a 12VDC VDC rating for telecom cabinets and network equipment. 29.9 Pa maximum pressure is the standout documented duty-point value. During wiring review, compare the model's static-pressure entry. Confirm environmental protection for the ordered version.

规格书:
MF60101V1-1000U-G99 | SUNON 12V 1.3W 60x60x10mm 27.7m3/h DC Axial Fan for Telecommunications 规格书 (Pdf)

产品特点

Rated Voltage(V)12VDC
Size(mm)60x60x10
Max.Air Flow(m³/h)27.7
Max.Pressure(Pa)29.9
Input Power(W)1.3
Speed(rpm)4000
Noise(db)28.5

产品特点

MagLev Cooling

Equipment builders can integrate SUNON MF60101V1-1000U-G99, a DC brushless axial fan, into telecommunications equipment. The design supplies the air movement required to carry component heat out of confined spaces.

The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market. Correct airflow direction and inlet clearance help translate the documented operating point into reliable equipment-level cooling.

Before adopting MF60101V1-1000U-G99, engineers should evaluate mounting rigidity. Carry out airflow mapping before ordering so the chosen fan can be released with clear installation and sourcing requirements. Review circulation around the components most sensitive to heat.

应用行业

常见问题

Why choose MF60101V1-1000U-G99 over a general cooling fan?

Its documented 12VDC VDC rating and 29.9 pa maximum pressure is the standout documented duty-point value. allow comparison with the required duty point without assuming unlisted options.

What voltage is required by MF60101V1-1000U-G99?

The listed rating is 12VDC VDC. Verify polarity or mains frequency, wiring, and protection before commissioning.

What should be checked if MF60101V1-1000U-G99 stops?

Verify supply, wiring, obstructions, impeller movement, and protection status. Use the model datasheet before replacement or repair.

Does MF60101V1-1000U-G99 have a documented pressure rating?

Yes. The worksheet lists up to 29.9 Pa; compare it with the system curve.

Which performance figures define MF60101V1-1000U-G99?

Use the listed voltage, size, 27.7 m³/h airflow, 4000 rpm, and 1.3 W input for preliminary comparison.

What equipment can use MF60101V1-1000U-G99?

It is listed for telecom cabinets and network equipment. Check dimensions, airflow, pressure, and the installation environment against the actual equipment.

在线留言