首页 > 产品 > 按类型 > 轴流风机 > PF40281B1-000U-G99 | SUNON 12V 6.12W 40x40x28mm 42.3m3/h DC Axial Fan for Data Center Cooling

PF40281B1-000U-G99 SUNON 轴流风机

品牌:
SUNON
型号:
PF40281B1-000U-G99 | SUNON 12V 6.12W 40x40x28mm 42.3m3/h DC Axial Fan for Data Center Cooling
类型:
轴流风机
应用行业:
数据中心冷却
产品描述:

Within servers and data-center electronics, SUNON PF40281B1-000U-G99 serves as a 40 × 40 × 28 mm DC axial fan operating at 12 VDC. 17600 rpm is the model's most distinctive operating parameter. Use the documented application data when planning spares assessment. Confirm control inputs against the complete ordering code.

规格书:
PF40281B1-000U-G99 | SUNON 12V 6.12W 40x40x28mm 42.3m3/h DC Axial Fan for Data Center Cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)12
Size(mm)40x40x28mm
Max.Air Flow(m³/h)42.3
Max.Pressure(Pa)510.6
Input Power(W)6.12
Speed(rpm)17600
Noise(db)56

产品特点

Reliable Fan Cooling

For server and data-center equipment, SUNON PF40281B1-000U-G99 serves as a DC brushless axial fan. The fan supports temperature control in equipment that runs through sustained or repeated duty cycles.

The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market. Correct airflow direction and inlet clearance help translate the documented operating point into reliable equipment-level cooling.

To integrate PF40281B1-000U-G99 effectively, review outlet geometry at equipment level and arrange power-budget review during sourcing review. Confirmed system compatibility supports stable cooling and repeatable procurement. Confirm startup and steady-state demand against the available supply.

应用行业

常见问题

What speed is listed for PF40281B1-000U-G99?

The listed speed is 17600 rpm. Confirm frequency, control method, and duty point for the installed system.

Is PF40281B1-000U-G99 suitable for continuous operation?

The supplied product-line reference discusses long-life cooling, but continuous-duty limits for this full suffix must be verified from its datasheet and operating conditions.

Does PF40281B1-000U-G99 have a documented pressure rating?

Yes. The worksheet lists up to 510.6 Pa; compare it with the system curve.

How should PF40281B1-000U-G99 be matched to an enclosure?

Review its 40 × 40 × 28 mm size, 42.3 m³/h airflow, 510.6 Pa pressure, system resistance, and available mounting space.

What certification information is listed for PF40281B1-000U-G99?

The workbook marks the product as RoHS compliant. Confirm UL, TUV, VDE, or other project-specific approvals for the exact suffix.

Which selection data still require confirmation for PF40281B1-000U-G99?

Confirm any missing bearing, connector, control, IP rating, life, certification, and performance-curve details for the complete part number.