首页 > 产品 > 按类型 > 轴流风机 > PF92251V2-10000-A99 | SUNON 12V 3.36W 92x92x25mm 118.9m3/h DC Axial Fan for Data Center Cooling

PF92251V2-10000-A99 SUNON 轴流风机

品牌:
SUNON
型号:
PF92251V2-10000-A99 | SUNON 12V 3.36W 92x92x25mm 118.9m3/h DC Axial Fan for Data Center Cooling
类型:
轴流风机
应用行业:
数据中心冷却
产品描述:

Within servers and data-center electronics, SUNON PF92251V2-10000-A99 serves as a 92 × 92 × 25 mm DC axial fan operating at 12 VDC. Up to 118.9 m³/h is its most prominent listed performance figure. Use the documented thermal-duty record when planning operating-cost analysis. Validate mounting and wiring from the model drawing.

规格书:
PF92251V2-10000-A99 | SUNON 12V 3.36W 92x92x25mm 118.9m3/h DC Axial Fan for Data Center Cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)12
Size(mm)92x92x25mm
Max.Air Flow(m³/h)118.9
Max.Pressure(Pa)74.7
Input Power(W)3.36
Speed(rpm)4200
Noise(db)43.7

产品特点

MagLev Cooling

SUNON PF92251V2-10000-A99 supports server and data-center equipment with DC brushless axial fan airflow. It is intended for installations where predictable air exchange is central to equipment stability.

SUNON's DC product line is developed around MagLev motor technology, supporting low-friction rotation, energy-conscious operation and long service life in compact formats.

For an orderly design-in process, assess vibration transfer around PF92251V2-10000-A99 and perform thermal-load testing in equipment qualification. The result is a clearer cooling specification for engineering, purchasing and maintenance teams. Compare installed temperatures at representative equipment loads. The final assembly should be tested under its expected thermal load.

应用行业

常见问题

What maintenance is recommended for PF92251V2-10000-A99?

Inspect for dust, blocked airflow, abnormal noise, loose mounting, and wiring damage. Isolate power before cleaning or service.

How can PF92251V2-10000-A99 affect operating cost?

Compare its listed 3.36 W input with the required airflow and run time. Total savings depend on the complete system duty point.

What voltage is required by PF92251V2-10000-A99?

The listed rating is 12 VDC. Verify polarity or mains frequency, wiring, and protection before commissioning.

Is PF92251V2-10000-A99 suitable for continuous operation?

The supplied product-line reference discusses long-life cooling, but continuous-duty limits for this full suffix must be verified from its datasheet and operating conditions.

What installation checks apply to PF92251V2-10000-A99?

Keep the airflow path clear, secure the frame without distortion, and follow the exact wiring diagram and voltage rating.

Which performance figures define PF92251V2-10000-A99?

Use the listed voltage, size, 118.9 m³/h airflow, 4200 rpm, and 3.36 W input for preliminary comparison.