首页 > 产品 > 按类型 > 轴流风机 > PF92252B1-10000-A99 | SUNON 24V 4.92W 92x92x25mm 127.4m3/h DC Axial Fan for Data Center Cooling

PF92252B1-10000-A99 SUNON 轴流风机

品牌:
SUNON
型号:
PF92252B1-10000-A99 | SUNON 24V 4.92W 92x92x25mm 127.4m3/h DC Axial Fan for Data Center Cooling
类型:
轴流风机
应用行业:
数据中心冷却
产品描述:

SUNON PF92252B1-10000-A99 combines a 92 × 92 × 25 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. Up to 127.4 m³/h is its most prominent listed performance figure. The recorded suffix definition should guide operating-cost analysis. Validate mounting and wiring from the model drawing.

规格书:
PF92252B1-10000-A99 | SUNON 24V 4.92W 92x92x25mm 127.4m3/h DC Axial Fan for Data Center Cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)24
Size(mm)92x92x25mm
Max.Air Flow(m³/h)127.4
Max.Pressure(Pa)87.2
Input Power(W)4.92
Speed(rpm)4500
Noise(db)46.1

产品特点

Reliable Fan Cooling

Designed for server and data-center equipment, the SUNON PF92252B1-10000-A99 provides DC brushless axial fan cooling in a format suited to equipment integration. It helps limit local heat buildup during operation.

The brushless DC motor architecture supports efficient electronic commutation and stable rotational performance for compact equipment cooling. Acoustic performance depends on the enclosure and operating point; low-turbulence integration helps avoid additional airflow noise.

The final PF92252B1-10000-A99 selection should consider connector reach as part of the installation layout. Finishing thermal-load testing in equipment qualification helps reduce integration uncertainty and supports reliable equipment cooling. Compare installed temperatures at representative equipment loads.

应用行业

常见问题

Which performance figures define PF92252B1-10000-A99?

Use the listed voltage, size, 127.4 m³/h airflow, 4500 rpm, and 4.92 W input for preliminary comparison.

Can PF92252B1-10000-A99 serve high-reliability cooling systems?

Assess reliability from the exact bearing, temperature, protection, and life data. The supplied series note alone does not confirm every suffix-specific option.

What protection rating does PF92252B1-10000-A99 have?

The exact IP or protection option is not stated in the supplied row. Confirm the full suffix in the applicable SUNON datasheet.

Is PF92252B1-10000-A99 compatible with a replacement fan?

Match voltage, dimensions, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.

How should buyers confirm availability of PF92252B1-10000-A99?

Stock and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.

What speed is listed for PF92252B1-10000-A99?

The listed speed is 4500 rpm. Confirm frequency, control method, and duty point for the installed system.